College Park, Fulton County

Atlanta Airport Marriott - Outdoor

4711 BEST RD COLLEGE PARK, GA 30337

Pool
Latest score
78
May 26, 2026
City
College Park
County
Fulton
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 26, 2026

Permit/Opening

Score: 783 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed free chlorine below the required minimum based off the code.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

Observed pool inability to turnover within 6hrs.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed loose handrails around the pool.

Jul 8, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 15, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 16, 2023

Re-inspection

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Need flow meter operational. code> (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

Jun 6, 2023

Permit/Opening

Score: 972 violations

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

missing permanently affixed universal international symbol for “NO DIVING” - provide.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed cracks in plaster bottom of pool - Code: Section 4.(9)(d) Material Surfaces. All surfaces that come in contact with the user shall be finished so that they do not constitute a cutting, pinching, puncturing or abrasion hazard under casual contact and intended use. All materials shall be maintained in accordance with manufacturer's instructions.