Brunswick, Glynn County

Brunswick Aquatic Center Lap Pool

1402 SONNY MILLER WAY BRUNSWICK, GA 31520

Pool
Latest score
98
May 8, 2026
City
Brunswick
County
Glynn
Inspections
9

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 8, 2026

Permit/Opening

Score: 981 violation

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Observed deck tile near starting board cracked with missing pieces.CA: Repair tile by replacing or filling in and sealing to ensure smooth finish.

Aug 8, 2025

Routine

Score: 951 violation

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed combined chlorine above 0.4ppm at the time of this inspection. CA: Lower to 0.4ppm or less.

Jun 10, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 5, 2025

Permit/Opening

Score: 815 violations

4 - water clarity: main drains clearly visible

Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e

15 ptsCorrected: NoRepeat: No

Could not observe the bottom of the pool or view the main drains. CA: Ensure pool clear and main drains can be seen at all time.

** Pool experiencing severe air in piping resulting in return inlets not functioning properly, poor circulation, and improper chemicals in the pool. Repair to ensure pool properly working.

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Observed facility chlorine levels below 2ppm at the time of this inspection. CA: Increase chlorine levels 2-10ppm.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH too low or too high in different areas due to poor circulation.

8 - chemical feeder operational and approved

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Its believed that chemical feeder is clogged and not feeding chlorine into the pool. CA: Repair to ensure constantly introducing chlorine into the pool.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(a) - (a) pools shall use wall or floor inlets that are adequate in design, number and location to provide adequate mixing.

4 ptsCorrected: NoRepeat: No

Return inlets bubbling indicating a leak in the piping. CA: repair to ensure properly circulating water.

Aug 30, 2024

Routine

Score: 961 violation

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

Observed pressure gauges on filters not reading at the time of this inspection. CA: Repair.

Aug 29, 2024

Routine

Score: 814 violations

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Observed facility chlorine levels below 2ppm at the time of this inspection. CA: Increase chlorine levels 2-10ppm.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH levels below 7.2 at the time of this inspection.

8 - chemical feeder operational and approved

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Observed chemical feeder readings not matching manual readings. Therefore not feeding properly. CA: Repair.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

Observed pressure filters not reading at the time of this inspection. CA: Repair.

May 21, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 1, 2023

Routine

Score: 942 violations

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(a) - (a) pools shall use wall or floor inlets that are adequate in design, number and location to provide adequate mixing.

4 ptsCorrected: NoRepeat: No

Observed multiple inlet covers missing at the time of this inspection. CA: Replace missing inlet covers.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(i) - (i) a four foot minimum continuous unobstructed deck, which may include the coping, shall be provided around at least 50 percent or more of a spa.

2 ptsCorrected: NoRepeat: No

Observed severe build up of debris on main drain covers at the time of this inspection. CA: Ensure pool is cleaned regularly to prevent build up of trash and debris and to ensure main drains are not clogged at any time.

May 18, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.