SEA ISLAND, Glynn County

Ocean Villas Spa (Cloister)

35 DUNE AVE SEA ISLAND, GA 31561

Pool
Latest score
91
Mar 27, 2026
City
SEA ISLAND
County
Glynn
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 27, 2026

Permit/Opening

Score: 912 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter non-operational at the time of this inspection. CA: CPO has placed an order for a new flow meter and will replace it once it arrives.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed CYA level above 90ppm at the time of this inspection. CA: Lower CYA level to 90ppm or below.

Mar 26, 2026

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

Observed emergency phone non-operational at the time of this inspection. CA: Replace emergency phone.

Oct 1, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Mar 27, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Mar 28, 2024

Permit/Opening

Score: 951 violation

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: Yes

Observed a combined chlorine >0.4ppm at the time of this inspection. CA: Lower combined chlorine to 0.4ppm or less.

Nov 29, 2023

Routine

Score: 912 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed a combined chlorine of 0.45ppm at the time of this inspection. CA: Lower combined chlorine to 0.4ppm or less.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed a CYA level of "Hi" at the time of this inspection. CA: Lower CYA to 90ppm or below.