Calhoun, Gordon County

COMFORT INN & SUITES POOL

1033 FAIRMOUNT HWY CALHOUN, GA 30701

Pool
Latest score
93
May 8, 2026
City
Calhoun
County
Gordon
Inspections
10

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 8, 2026

Re-inspection

Score: 932 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: YesRepeat: No

Observed combined chlorine greater than 0.4ppm (refer to water quality readings below). Corrective Action: Informed RPC combined chlorine cannot be greater than 0.4ppm from free chlorine reading. RPC to adjust combined chlorine levels.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Observed missing pool risks. CA: “Pool Risks” items listed in clearly legible letters at least one inch high. No COS. RPIC must post pool risks.

May 5, 2026

Routine

Score: 784 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed main pool door not self-latching. CA: Doors to pool enclosure should be self-latching. No COS can be observed. Workorder placed to have door repaired. Inspector must return to verify door is self-latching before pool can re-open.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH lower than 7.2 (pH=7.1 @ 5' end and 6.4 @ 3' end). CA: Proper pH levels between 7.2 and 7.8. No COS. pH must be adjusted and inspector must be contacted to recheck pH prior to pool opening.

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed combined chlorine greater than 0.4ppm (refer to water quality readings below). Corrective Action: Informed RPC combined chlorine cannot be greater than 0.4ppm from free chlorine reading. RPC to adjust combined chlorine levels.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Observed missing pool risks. CA: “Pool Risks” items listed in clearly legible letters at least one inch high. No COS. RPIC must post pool risks.

Dec 15, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Dec 11, 2025

Routine

Score: 802 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed free chlorine levels greater than 10 ppm (11.82 ppm), with appropriate levels being between 1-10 ppm. Corrective Action: RPC notified, free chlorine levels will be adjusted.

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed combined chlorine greater than 0.4ppm from free chlorine (refer to water quality readings below). Corrective Action: Informed RPC combined chlorine cannot be greater than 0.4ppm from free chlorine reading. RPC to adjust combined chlorine levels.

Jul 29, 2025

Routine

Score: 932 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: YesRepeat: Yes

Observed combined chlorine greater than 0.4ppm from free chlorine (refer to water quality readings below). Corrective Action: Informed RPC combined chlorine cannot be greater than 0.4ppm from free chlorine reading. RPC to adjust combined chlorine levels.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed pool ladder at 5' depth marker not tightly secured to deck. CA: Workorder placed to get ladder secured.

Apr 2, 2025

Re-inspection

Score: 951 violation

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: YesRepeat: No

Observed combined chlorine greater than 0.4ppm from free chlorine (refer to water quality readings below). Corrective Action: Informed RPC combined chlorine cannot be greater than 0.4ppm from free chlorine reading. RCP to adjust combined chlorine levels.

Mar 25, 2025

Permit/Opening

Score: 803 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed door to pool near restrooms not self-latching. Corrective Action: Work order placed to ensure door to pool is latching.

18 - combined chlorine level 0.4 ppm or less

5 ptsCorrected: NoRepeat: No

Observed no proper 911 signage in clear view of the pool. Corrective Action: Emergency sign with 911 to be placed above emergency telephone.

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed combined chlorine level greater than the maximum 0.4 ppm. Reading was high. Corrective Action: adjust combined chlorine to be 0.4 ppm or less.

Mar 5, 2025

Routine

Score: 805 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed door to pool not latching. Corrective Action: Work order placed to ensure door to pool is latching.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone not operational. Corrective Action: Work order placed to have emergency phone repaired.

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed free chlorine levels greater than 10 ppm, with appropriate levels being between 1-10 ppm. Corrective Action: PIC notified, CPO will adjust free chlorine levels.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH higher than 7.8 with proper levels between 7.2-7.8. Corrective Action: CPO to adjust pH levels to proper levels between 7.2-7.8.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter reading 55gpm with pool required turnover rate at 70gpm. Corrective Action: PIC notified, pool required turnover rate is 70gpm.

Mar 5, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jan 31, 2024

Routine

Score: 778 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed door to pool not latching. Corrective Action: PIC was notified, work order placed to ensure door to pool is latching.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone not operational. Corrective Action: PIC was notified, work order placed to have emergency phone repaired.

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed free chlorine levels greater than 10 ppm, with appropriate levels being between 1-10 ppm. Corrective Action: PIC was notified, CPO notified and will adjust free chlorine levels.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH lower than 7.2 with proper levels between 7.2-7.8. Corrective Action: PIC was notified, CPO to adjust pH levels to proper levels between 7.2-7.8.

10 - pump: approved, maintained and operating

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Observed inoperable pump and flow meter. Corrective Action: PIC was notified, workorder placed for pump.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed inoperable flow meter. Corrective Action: PIC was notified, workorder placed to have flow meter repaired.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed pool ladder not secured to deck. Corrective Action: PIC was notified, workorder placed to get ladder repaired.

30 - deck/rinse shower maintained

Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.

1 ptsCorrected: NoRepeat: No

Observed inoperable shower station, shower station not supplied with water. Pull arm needs to be replaced. Corrective Action: PIC was notified, work order placed to have water supplied to shower station and pull arm replaced.