Gainesville, Hall County

WENDY'S OLD FASHIONED HAMBURGERS #20

416 SHALLOWFORD RD GAINESVILLE, GA 30504

Food
Latest score
96
Jan 22, 2026
City
Gainesville
County
Hall
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jan 22, 2026

Routine

Score: 961 violation

2-2D - adequate handwashing facilities supplied & accessible

Regulation: 511-6-1.06(2)(c) - handwashing sinks, installation (pf, c)

4 ptsCorrected: NoRepeat: No

Observed both Women's Restroom Hand Sinks to be unable to reach a peak temperature of at least 85°F. Please see Comments section for specific temperatures.

Handwashing sinks, Installation (Pf, C) (c) Handwashing Sink Installation.

  1. A handwashing sink shall be equipped to provide tempered water at a temperature of at least 85ºF (29.4 ºC) through a mixing valve or combination faucet. Pf

Note: PIC put in a service ticket during the inspection to repair the hand sinks.

Jul 22, 2025

Routine

Score: 981 violation

16A - hot and cold water available; adequate pressure

Regulation: 511-6-1.06(1)(g),(h) - water supply, capacity; pressure (pf)

2 ptsCorrected: NoRepeat: No

Observed the hot water, at the mop, to have a final temperature of 85F and there to be no access to cold water. The water source and system shall be of sufficient capacity to meet the peak water demands of the food service establishment. PIC to put in work order to ensure that the mop sink can provide hot and cold water.

Jan 17, 2025

Routine

Score: 961 violation

2-2D - adequate handwashing facilities supplied & accessible

Regulation: 511-6-1.06(2)(c) - handwashing sinks, installation (pf, c)

4 ptsCorrected: NoRepeat: No

Observed hand sink in men's restroom to have a peak temperature at 88F.

511-6-1.06(2)(c) - Handwashing sinks, Installation (Pf, C) (c) Handwashing Sink Installation.

  1. A handwashing sink shall be equipped to provide tempered water at a temperature of at least 100ºF (38ºC) through a mixing valve or combination faucet. Pf

Jul 12, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jan 11, 2024

Routine

Score: 961 violation

2-2D - adequate handwashing facilities supplied & accessible

Regulation: 511-6-1.06(2)(c) - handwashing sinks, installation (pf, c)

4 ptsCorrected: NoRepeat: No

Observed hand sink in women's restroom to have a peak temperature at 96F. Observed one hand sink in women's restroom to not turn on, when attempting to wash hands.

A handwashing sink shall be equipped to provide tempered water at a temperature of at least 100ºF (38ºC) through a mixing valve or combination faucet.

A self-closing, slow-closing, or metering faucet shall provide a flow of water for at least 15 seconds without the need to reactivate the faucet.

Note: PIC will call appropriate personnel to come in facility and repair both hand sinks, so that they are in compliance with the regulations.

Jul 26, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.