Jun 11, 2026
Routine
4-2B - food-contact surfaces: cleaned & sanitized
Regulation: 511-6-1.05(6)(n) - manual and mechanical warewashing equipment, chemical sanitization-temperature, ph, concentration, hardness (p,pf)
Observed quaternary ammonium sanitizer did not meet the minimum concentration requirement of 150-400 ppm in the three compartment sink. PIC was coached on washing, rinsing, and sanitizing dishes in the three compartment sink. Once the quat sanitizer was remade, the concentration of quaternary ammonium was observed at 200 ppm.
511-6-1.05(6)(n) - Manual and Mechanical Warewashing Equipment, Chemical Sanitization-Temperature, pH, Concentration, Hardness (P,Pf) (n) Manual and Mechanical Warewashing Equipment, Chemical Sanitization - Temperature, pH, Concentration, and Hardness. A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation at contact times specified under subsection (8)(b)3 of this Rule shall meet the requirements specified in DPH Rule 511-6-1-.07(6)(g), shall be used in accordance with the Environmental Protection Agency (EPA)-registered label use instructions P, and shall be used as follows:
- A chlorine solution shall have a minimum temperature based on the concentration and pH of the solution as listed in the following chart; P
Concentration Range Minimum Temperature
MG/L PH 10 or less oF (oC) PH 8 or less oF (oC)
25-49 120 (49) 120 (49)
50-99 100 (38) 75 (24)
100 55 (13) 55 (13)
-
An iodine solution shall have a minimum temperature of 68°F (20°C)P minimum concentration between 12.5 ppm and 25 ppm, P and pH of 5.0 or less or a pH no higher than the level for which the manufacturer specifies for the solution to be effective; P
-
A quaternary ammonium compound solution shall have a minimum temperature of 75ºF (24ºC), P have a concentration as specified in DPH Rule 511-6-1-.07(6)(g) and as indicated by the manufacturer’s use directions included in the labeling, P and be used only in water with 500 ppm hardness or less or in water having a hardness no greater than specified by the EPA-registered label use instructions; P
-
If another solution of a chemical specified under paragraphs 1 through 3 of this subsection is used, the permit holder shall demonstrate to the Health Authority that the solution achieves sanitization and the use of the solution shall be approved; P
-
If a chemical sanitizer other than chlorine, iodine, or a quaternary ammonium compound is used, it shall be applied in accordance with the EPA-registered label use instructions ;P and
-
If a chemical sanitizer is generated by a device located on-site at the food service establishment, it shall be used as specified in 1-5 of this subsection and shall be produced by a device that:
(i) complies with law as specified in sections 2(q)(1) and 12 of the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA), P
(ii) complies with 40 CFR 152.500 Requirement for Devices and 40 CFR 156.10 Labeling Requirements, P
(iii) displays the EPA device manufacturing facility registration number on the device, Pf and
(iv) is operated and maintained in accordance with manufacturer’s instructions. Pf.
- On-site chemical sanitizer generating equipment with active ingredients, such as copper, must be registered as pesticides. The active ingredient may be part of the equipment or separately added.
11C - approved thawing methods used
Regulation: 511-6-1.04(6)(c) - thawing (c)
Observed shrimp and salmon thawing improperly in the preparation sink. PIC advised to run cold water while draining when thawing TCS foods
511-6-1.04(6)(c) - Thawing (C) (c) Thawing. Except as specified in paragraph 4 of this subsection, time/temperature control for safety food shall be thawed:
-
Under refrigeration that maintains the food temperature at 41°F (5°C) or less; PF or
-
Completely submerged under running water:
(i) At a water temperature of 70°F (21°C) or below, PF
(ii) With sufficient water velocity to agitate and float off loose particles in an overflow PF, and
(iii) For a period of time that does not allow thawed portions of ready-to-eat food to rise above 41°F (5°C), or
(iv) For a period of time that does not allow thawed portions of a raw animal food requiring cooking to be above 41°F (5°C), for more than 4 hours including:
(I) The time the food is exposed to the running water and the time needed for preparation for cooking PF, or
(II) The time it takes under refrigeration to lower the food temperature to 41°F (5°C) PF;
- As part of a cooking process if the food that is frozen is:
(i) Cooked as specified under subsections (5)(a)1 or 2 or (5)(b) or 5(e) of this Rule PF, or
(ii) Thawed in a microwave oven and immediately transferred to conventional cooking equipment, with no interruption in the process PF; or
-
Using any procedure if a portion of frozen ready-to-eat food is thawed and prepared for immediate service in response to an individual consumer's order.
-
Reduced oxygen packaged fish that bears a label indicating that it is to be kept frozen until time of use shall be removed from the reduced oxygen environment:
(i) Prior to its thawing under refrigeration that maintains the food temperature at 41°F (5°C) or less; or
(ii) Prior to, or immediately upon completion of its thawing, using procedures to completely submerge in running water as specified in paragraph 2 of this subsection.
17B - garbage/refuse properly disposed; facilities maintained
Regulation: 511-6-1.06(5)(n) - covering receptacles (c)
Observed the trash bin in bad repair.
511-6-1.06(5)(n) - Covering Receptacles (C) (n) Covering Receptacles. Receptacles and waste handling units for refuse, recyclables, and returnables shall be kept covered:
- Inside the food service establishment if the receptacles and units:
(i) Contain food residue and are not in continuous use; or
(ii) After they are filled; and
- With tight-fitting lids or doors if kept outside the food service establishment.
17C - physical facilities installed, maintained, and clean
Regulation: 511-6-1.07(2)(a) - floor, walls, & ceilings, cleanability (c)
17C. Observed non-approved ceiling tile installed above the small bar area. Install durable, washable non- porous type ceiling tile above the small bar area.
17D - adequate ventilation and lighting; designated areas used
Regulation: 511-6-1.07(4)(b) - designated areas for employee activity, located to prevent contamination of food, equipment, utensils, linens, & single service articles (c)
Observed employee belongings (bags) improperly stored in the kitchen and storage area. PIC will designate a separate area for employee belongings to prevent contamination.