Feb 2, 2026
Routine
4-2B - food-contact surfaces: cleaned & sanitized
Regulation: 511-6-1.05(6)(n) - manual and mechanical warewashing equipment, chemical sanitization-temperature, ph, concentration, hardness (p,pf)
Observed 0 parts per million (ppm) of sanitizer solution inside three sanitizer buckets in the main kitchen, and coming out of the dispenser. A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation at contact times specified under subsection (8)(b)3 of this Rule shall meet the requirements specified in DPH Rule 511-6-1-.07(6)(g), shall be used in accordance with the Environmental Protection Agency (EPA)-registered label use instructions P, and shall be used as follows A quaternary ammonium compound solution shall have a minimum temperature of 75ºF (24ºC), P have a concentration as specified in DPH Rule 511-6-1-.07(6)(g) and as indicated by the manufacturer’s use directions included in the labeling, P and be used only in water with 500 ppm hardness or less or in water having a hardness no greater than specified by the EPA-registered label use instructions. Have sanitizer dispenser serviced. Manager contacted ECOLAB for assistance. Alternative methods for making sanitizer provided.