1000 REDWOOD LN ATHENS, GA 30606
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
FLOW RATE TOO LOW
INSPECTION REPORT IN OFFICE AND NOT PUBLICLY DISPLAYED
Permit/Opening
Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.
Make sure to fill holes under bricks & secure bricks. Send pictures to OCHD.
Permit/Opening
Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
FLOW RATE NOT ADEQUATE. MUST BE 502 GPM.
Permit/Opening
Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type
Permit/Opening
Regulation: .17((1)(c) - proper disinfectant level
1.2 PPM FREE CHLORINE. MUST BE 2-10PPM
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
pH 8.0+. MUST BE 7.2-7.8
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
FLOW METER OUT
Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.
PRESSURE GAUGES OUT
Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
MISSING BATHER LOAD SIGN