Byron, Peach County

COMFORT SUITES

103 DUNBAR RD BYRON, GA 31008

Pool
Latest score
94
Apr 24, 2026
City
Byron
County
Peach
Inspections
12

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 24, 2026

Routine

Score: 942 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

The combined chlorine level is 1.36ppm; above the minimum requirement of 0.40ppm

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed calcium hardness level below the minimum requirements at 79 ppm. Minimum requires level is 150ppm.

Dec 17, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 30, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 9, 2025

Routine

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter not operational at time of inspection. A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. Repair/replace flow meter.

Feb 11, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jan 15, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Dec 27, 2024

Permit/Opening

Score: 942 violations

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Observed no "No Diving" markers present. Current marker is written out on (1) 4 inch tile. Letters must be a minimum of four inches.

511-3-5-.18(3)(h) - (h) Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. (h) Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

"No Diving" sign with 4 inch letters required.

511-3-5-.18(12)(a) - (a) The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou (a) The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers in subsections (3)(a) thru (h) above.

Aug 29, 2024

Routine

Score: 932 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

The combined chlorine level is 1.42ppm; above the minimum requirement of 0.40ppm

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Both front pool Hand rails/ ladders are loose. They were able to be pulled about 2-3 inches from base. Rails are to be resecured at base on deck.

511-3-5-.06(3)(f)1. - 1. Handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

  1. Handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

Feb 6, 2024

Routine

Score: 942 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

The combined chlorine level is 1.14ppm; above the minimum requirement of 0.40ppm

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.

1 ptsCorrected: NoRepeat: No

Observed no soap in women's restroom.

11-3-5-.19(2)(i) - (i) Soap, paper towels, and toilet tissue shall be provided in all dispensers. (i) Soap, paper towels, and toilet tissue shall be provided in all dispensers.

Dec 6, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 29, 2023

Routine

Score: 951 violation

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Observed combined chlorine above the maximum level at .89ppm

Jun 29, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.