Augusta, Richmond County

AUGUSTA AQUATICS CENTER LAP POOL

3157 DAMASCUS RD AUGUSTA, GA 30904

Pool
Latest score
97
Jun 11, 2026
City
Augusta
County
Richmond
Inspections
11

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 11, 2026

Routine

Score: 972 violations

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed loose rails around pool. C/A - tighten all loose handrails.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed Total Alkalinity at 40 ppm. C/A - adjust Total Alkalinity to at least 60 ppm. 511-3-5.22(12)

Jan 15, 2026

Routine

Score: 972 violations

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed loose handrails on side of pool C/A - tighten rails.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed total alkalinity at 40 ppm. C/A - adjust total alkalinity to between 60 and 180 ppm. 511-3-5.22(9)

Oct 10, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Oct 9, 2025

Routine

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed 911 phone not working. C/A - repair 911 phone so that it connects to 911 when calling out.

Jul 24, 2025

Routine

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed loose ladders on pool. C/A - tighten ladders

May 9, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jan 2, 2025

Permit/Opening

Score: 972 violations

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: Yes

Observed loose ladders on pool. C/A - tighten ladders

31 - dressing showers: clean, maintained, hot and cold water available

Regulation: 511-3-5-.19(1)(b) - (b) dressing facilities, when provided, shall be have separations for each sex with no interconnection. the rooms shall be well-lighted, drained, ventilated, and of good construction with impervious materials. they shall be developed and planned so t

1 ptsCorrected: NoRepeat: No

Observed missing fixture in men's shower. C/A - repair ASAP.

Nov 13, 2024

Routine

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed loos ladder on lap pool. C/A - repair ladder

Jan 3, 2024

Permit/Opening

Score: 961 violation

26 - gauge(s) in proper location; sight glass installed

4 ptsCorrected: NoRepeat: Yes

The gauge is broken.

Dec 28, 2023

Routine

Score: 912 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

The flow rate is 1050 gal/min. The flow rate should at least be 1542 gal/min.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

The gauge is broken.

Sep 14, 2023

Routine

Score: 912 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

The flow rate is 1100gal/min. The flow rate should at least be 1542 gal/min.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

The gauge is broken.