Augusta, Richmond County

GARNER HOTEL AUGUSTA WEST

629 FRONTAGE RD AUGUSTA, GA 30907

Pool
Latest score
100
Jun 11, 2026
City
Augusta
County
Richmond
Inspections
12

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 11, 2026

Routine

Score: 1000 violations
No violations recorded for this inspection.

Mar 30, 2026

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Need test kit with Free chlorine test (DPD#1, DPD#2).

Mar 18, 2026

Permit/Opening

Score: 802 violations

8 - chemical feeder operational and approved

Regulation: 511-3-5-.16(2)(a) - (a) every pool and spa shall be required to have at least one unit of disinfectant agent equipment that introduces the agent through the circulation system in compliance with this rule

15 ptsCorrected: NoRepeat: No

Need chlorinator that provides 4lbs free chlorine/day/10000 gallons; can maintain free chlorine level of 2.0ppm.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Need test kit for pool (free and total chlorine, pH. Need log book for pool).

Jun 18, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Apr 25, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Nov 7, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Aug 5, 2024

Re-inspection

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

CYA >> 100 ppm; should be below 90 ppm.

Jul 31, 2024

Routine

Score: 805 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Gate must self-close and latch (catches at top).

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone must be able to dial local 911 system (dial tone, no direct dial or keypad).

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

pH< 6.8; adjust to 7.2-7.8 range.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

CYA >> 100 ppm; should be below 90 ppm.

30 - deck/rinse shower maintained

Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.

1 ptsCorrected: NoRepeat: No

Shower not working.

Apr 4, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Apr 1, 2024

Permit/Opening

Score: 852 violations

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Free chlorine at 1.0ppm; should be 2.0ppm.

8 - chemical feeder operational and approved

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Chlorinator observed to have no flow through tube.

Dec 15, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jul 7, 2023

Complaint

Score: 851 violation

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: YesRepeat: No

pH<=7.0 Added soda ash to increase pH.