Augusta, Richmond County

PARTRIDGE INN POOL

2110 WALTON WAY AUGUSTA, GA 30904

Pool
Latest score
100
Mar 30, 2026
City
Augusta
County
Richmond
Inspections
11

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 30, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 31, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jul 29, 2025

Routine

Score: 851 violation

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Increase chlorine level to 2.0 ppm min. free chlorine.

Mar 19, 2025

Permit/Opening

Score: 851 violation

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: YesRepeat: No

pH was 8.0; added muriatic acid to adjust. Retested at 7.4

Dec 13, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Sep 6, 2024

Re-inspection

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Replace flowmeter (should be for 2" pipe).

Aug 29, 2024

Routine

Score: 852 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Latch on gate loose (latch plate); repair (gate latched at time of inspection).

8 - chemical feeder operational and approved

Regulation: 511-3-5-.16(2)(a) - (a) every pool and spa shall be required to have at least one unit of disinfectant agent equipment that introduces the agent through the circulation system in compliance with this rule

15 ptsCorrected: NoRepeat: No

Observed chlorine tablets in skimmer basket; chlorine must be maintained with operating chlorinator. No chlorinator observed. Install chlorinator that feeds 12 lbs chorine per day.

May 29, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Apr 22, 2024

Permit/Opening

Score: 795 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Free chlorine less than required 2.0ppm (tested salt level ~ 1700ppm)

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

pH > 8.0, should be 7.2-7.8. Adjust pH.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.

15 ptsCorrected: NoRepeat: No

Reach pole not 12" in length. Affix/attach shepherds hook to non extendible 12 foot reach pole.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type

5 ptsCorrected: NoRepeat: No

Flowmeter appeared to be missing float; replace flowmeter.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Test reagents expired; replace test reagents.

Aug 24, 2023

Re-inspection

Score: 981 violation

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Crack in coving by entrance.

Aug 21, 2023

Routine

Score: 795 violations

8 - chemical feeder operational and approved

15 ptsCorrected: NoRepeat: No

Severe leak on pump/chlorinator.

9 - filter: approved, maintained and operating

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Leak on system needs repair.

10 - pump: approved, maintained and operating

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Severe leak on system.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Cyanuric acid level above 90 ppm.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

2 ptsCorrected: NoRepeat: No

Light pulled out of socket (was told no power) place back in socket/holder.