Jun 5, 2026
Permit/Opening
1603 MCINTOSH ST VIDALIA, GA 30474
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed pH at 6.9.
Permit/Opening
Regulation: .17(1)(a)(b) - proper disinfectant level
Observed free chlorine level at 10.95
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed pH level at 7.0
Routine
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter at 65 gpm.
Permit/Opening
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter at 65 gpm. Minimum is 74 gpm.
Routine
Observed skimmer basket full of leaves and debris.
Permit/Opening
Observed skimmer full of debris.
Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.
Hand rail on the left side of the pool is loose.
Routine
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter reading at 55 gpm. Minimum is 74 gpm.
Routine
Regulation: .17((1)(c) - proper disinfectant level
Observed chlorine level above 10 with chemical test.
Routine
Regulation: .17((1)(c) - proper disinfectant level
Observed chlorine level above 10 with chemical test.
Routine
Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
Observed chlorine level at zero with chemical test.
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
Observed pH at 8.0 with chemical test. pH needs to be between 7.2 and 7.8.
Permit/Opening