Sandersville, Washington County

SanWar RV Park & Resort

1181 N GA 15 HWY SANDERSVILLE, GA 31082

Pool
Latest score
100
Apr 10, 2026
City
Sandersville
County
Washington
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 10, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 26, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Apr 29, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 14, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Aug 13, 2024

Routine

Score: 676 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed disinfectant level of 0 in upper pool. Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH of at least 8 in lower and upper pool. During operation, the pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter not working for upper pool. A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Observed no records at the facility. A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyanuric acid levels greater that 100. Stabilizer (if used) Cyanuric acid,ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

Observed no records at the facility. Written documentation of the operator’s visits must be available at the pool facility.

Jul 3, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.