Sandersville, Washington County

Quality Inn

508 S HARRIS ST SANDERSVILLE, GA 31082

Pool
Latest score
100
May 11, 2026
City
Sandersville
County
Washington
Inspections
10

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 11, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 1, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jul 30, 2025

Routine

Score: 803 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Chlorine level observed to be greater than 13.29. Sample run 3x. ree Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0 Owner/operator closed the pool voluntarily.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

pH observed to be 6.7. During operation, the pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7.

pH should be adjusted to proper level.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed some pool check parameters not completed, such as weekly alkalinity checks. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. An in-line sampling port may be used for water held in reservoirs. The water quality testing frequency shall be as follows: (a) For pools, free available chlorine or total bromine and pH shall be tested a minimum of two times daily during the hours of operation. (b) Total alkalinity shall be tested weekly and calcium hardness shall be tested monthly. (c) If stabilized chlorine is used as the primary disinfectant, the operator shall test cyanuric acid every two weeks. Otherwise, cyanuric acid shall be tested monthly. Cyanuric acid shall be tested twenty-four hours after addition to the water

May 20, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 27, 2024

Routine

Score: 842 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Dialed 911 to test phone. Phone dialed to a national 911 call center in Colorado. Operator stated that the phone shows "no location." An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

Pool is closed and cannot reopen until the phone calls local 911.

34 - inspection report placed in public view

Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

1 ptsCorrected: NoRepeat: No

No inspection report displayed. The operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

May 15, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 1, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Aug 29, 2023

Routine

Score: 763 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

pH observed to be 8. During operation, the pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: Yes

Records not available. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. An in-line sampling port may be used for water held in reservoirs. The water quality testing frequency shall be as follows: (a) For pools, free available chlorine or total bromine and pH shall be tested a minimum of two times daily during the hours of operation. (b) Total alkalinity shall be tested weekly and calcium hardness shall be tested monthly. (c) If stabilized chlorine is used as the primary disinfectant, the operator shall test cyanuric acid every two weeks. Otherwise, cyanuric acid shall be tested monthly. Cyanuric acid shall be tested twenty-four hours after addition to the water

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

Records not available. Written documentation of the operator’s visits must be available at the pool facility.

Jun 27, 2023

Routine

Score: 951 violation

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. An in-line sampling port may be used for water held in reservoirs. The water quality testing frequency shall be as follows: (a) For pools, free available chlorine or total bromine and pH shall be tested a minimum of two times daily during the hours of operation. (b) Total alkalinity shall be tested weekly and calcium hardness shall be tested monthly. (c) If stabilized chlorine is used as the primary disinfectant, the operator shall test cyanuric acid every two weeks. Otherwise, cyanuric acid shall be tested monthly. Cyanuric acid shall be tested twenty-four hours after addition to the water

May 17, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.