May 19, 2026
Permit/Opening
6065 HARRISON RD MACON, GA 31206
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter stuck in position. b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications. EHS informed the CPO who is going to address the issue.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Observed skimmer weir missing on one of the skimmers. (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.EHS informed the PIC of the need to purchase a new weir.
Observed facility without pool risk signage.
Routine
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Observed 911 signage and facility address not listed at the emergency phone. (c) An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby. EHS informed the GM and CPO of the need to post the signage.
Regulation: .17((1)(c) - proper disinfectant level
Observed no chlorine in the pool. (c) Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0. EHS informed the GM (on-site) and the CPO via phone of the chlorine levels.
Regulation: 511-3-5-.22(1) - (1) all swimming pools and spas covered by this chapter shall be maintained under the supervision and direction of a properly trained operator who shall be responsible for the sanitation, safety, and proper maintenance of the pool and all related equ
Observed facility without the water test logs. Per GM, the CPO has the logs with him. (1) All swimming pools and spas covered by this Chapter shall be maintained under the supervision and direction of a properly trained operator who shall be responsible for the sanitation, safety, and proper maintenance of the pool and all related equipment, and for and daily recordkeeping. EHS informed the GM that the logs are to remain on-site.
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Observed cyanuric acid at 110 ppm. (4) Stabilizer (if used) Cyanuric acid,ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or brominated pools and spas. EHS informed the GM(Omar) on-site and the CPO via phone of the high levels.
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
Observed the facility without CPO certification on-site. (1) All swimming pools and spas covered by this Chapter shall be maintained under the supervision and direction of a properly trained operator who shall be responsible for the sanitation, safety, and proper maintenance of the pool and all related equipment, and for and daily recordkeeping. EHS informed the GM of the need to keep a copy of the CPO certification on-site.
Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:
Observed pool without risk signage. (4) Stabilizer (if used) Cyanuric acid,ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or brominated pools and spas. EHS informed the GM(Omar) on-site and the CPO via phone of the need to post signage. The GM stated that the signage had been ordered.
Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis
Observed facility without complete “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY” signage. (b) Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”. EHS informed the GM and the CPO of the need to purchase the correct signage.
Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
Observed facility without the bather load posted in 4 inch numbering. A sign stating the occupancy shall be posted in a visible location near the entrance in four inch letters and numbers. The maximum number of bathers to be allowed in a pool enclosure at one time shall be based on DPH Rule 511-3-5-.05(12). Facility will need to post the bater load in 4 inch numbering on or near the entrance gate.
Permit/Opening
Permit/Opening
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
EHS observed that landline phone does not have listed address for location.
The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available.
PIC to ensure phone has signage for address or update address with provider.
Regulation: .17(1)(a)(b) - proper disinfectant level
EHS observed TCl at .29, FCl at .15.
Free chlorine,ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
CPO to adjust sanitizer to appropriate levels.
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
EHS observed pH at 8.3.
pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7.