Jun 12, 2026
Permit/Opening
4709 CHAMBERS RD MACON, GA 31206
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Regulation: .17((1)(c) - proper disinfectant level
Observed no chlorine present. (c) Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0EHS informed PIC to notify the CPO to balance the water chemistry.
Observed low alkalinity levels. EHS informed the PIC of the need to inform the CPO to balance the water chemistry.
Permit/Opening
Regulation: .17((1)(c) - proper disinfectant level
Observed no chlorine present. (c) Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0EHS informed PIC to notify the CPO to balance the water chemistry.
Observed flow meter not working. (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications. EHS informed the GM that the flow meter needed to be cleaned OR replaced and that it should read an accurate flow rate.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Observed skimmer weir missing. (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. EHS informed the PIC of the need to install the skimmer weir.
Observed low alkalinity and calcium hardness levels. EHS informed the PIC of the need to inform the CPO to balance the water chemistry.
Permit/Opening
Permit/Opening
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Observed emergency phone was not operationing(no dial tone) c) An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby. EHS informed the GM of the need to have the phone fixed with the ability to dial to Macon-Bibb 911.
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Observed 911 signage and facility contact information needing to be posted at the emergency phone. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby. EHS informed the GM of the need to post the noted information.
Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch
Observed facility's need to purchase a new throwing rope and life ring. (b) A minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inches or a similar flotation device which is U.S. Coast Guard approved. EHS informed the GM of the need to purchase a new ring and rope.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter not working. (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications. EHS informed the GM that the flow meter needed to be replaced and that it should read an accurate flow rate.
Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.
Observed the guage on the filter not operating effectively. a) A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.EHS informed the GM of the need to have the filter and gauge serviced.
Regulation: 511-3-5-.09(9)(a) - (a) the pump vacuum gauge shall be installed as close to the suction side of the pump as possible while still maintaining an accurate reading.
Observed only one main drain and the need to need to install a Vac-Alert system(vacuum gauge). (a) The pump vacuum gauge shall be installed as close to the suction side of the pump as possible while still maintaining an accurate reading. EHS informed the GM of the need to install this equipment.
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
Observed no CPO certification on-site. (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority. EHS informed the GM of the need to have a copy of the pool operator's certification on-site.
Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
Observed the NO DIVING symbol needing to be installed in four more areas around the pool deck. (a) The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers in subsections (3)(a) thru (h) above. EHS informed the GM of the need to install the NO DIVING symbols.
Observed low calcium hardness level; chlorine tablets in the skimmer basket. EHS informed the GM that that water chemistry needed to be balanced and that the chlorine tablets must be fed through the chlorinator.
Observed facility's need to install a drinking fountain on the water line that sources the shower. EHS informed the GM of the need to install a drinking fountain.
Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.
Observed plumbing needing to be marked with the direction of water flow and what each line sources. (6) All piping shall be marked with directional arrows as necessary to determine flow direction. All piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves. EHS informed the GM to label the plumbing.
Observed the pump/filter/disinfection system not on when arriving at the facility. EHS questioned the GM on how long it had been off and he stated since yesterday. EHS informed him that the pump/filter/disinfection system should be operating at all times. EHS turned on system to see if it was working; system was not operating effectively.