Apr 1, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 30, 2025

Routine

Score: 812 violations

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

EHS observes life rings missing appropriate safety lines.

A minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inches or a similar flotation device which is U.S. Coast Guard approved.

PIC to obtain correct lines for life rings.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Observed depth markers letters of 'No Diving' not meeting the four inch min requirement.

(h) Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Informed PIC for next pool season that facility could either purchase stencils, or purchase non-slip/slip resistance no diving stickers with 4 inch lettering.

PIC to correct lettering.

Apr 21, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 12, 2024

Routine

Score: 903 violations

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Observed depth markers letters of 'No Diving' not meeting the four inch min requirement.

(h) Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Informed PIC for next pool season that facility could either purchase stencils, or purchase non-slip/slip resistance no diving stickers with 4 inch lettering. This must be corrected by 08/14/24

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

When EHS went to ask for CPO certification, Maintenance manager, informed EHS that the class was canceled to renew CPO certification, and is looking to enroll in class again. Maintenance manager informed EHS that he's had the certification for 5 years it just hasn't been renewed. (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.

Informed maintenance manager, in order for pool to operate there must be a CPO present with license. Maintenance manager is to obtain CPO license. This must be corrected by 08/15/24

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

EHS observed loose grab/hand rails in the 5 foot area of swimming pool

  1. Handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools. Informed PIC to have grab/hand rails repaired or replaced. This must be corrected by 08/14/24