Kingsland, Camden County

Laurel Landing Pool

202 LAUREL LANDING BLVD KINGSLAND, GA 31548

Pool
Latest score
95
Mar 17, 2026
City
Kingsland
County
Camden
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 17, 2026

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

At time of inspection, the flow meter is on-site, but is not yet installed. CPO states the flow meter will be installed ASAP.

Nov 3, 2025

Routine

Score: 912 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

At time of inspection, the flow meter is missing. Replace the flow meter.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) level registered at 213 ppm (CYA must be 90 ppm or less). Pool will be drained and resurfaced next week, per CPO.

Apr 8, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Oct 4, 2024

Re-inspection

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

At time of inspection, it appeared that the flow meter from the pool was moved to the wading pool piping when the chlorinator was installed on the wading pool. CPO will add a flow meter.

Sep 23, 2024

Routine

Score: 853 violations

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

At time of inspection, the disinfectant level was below the minimum (observed free chlorine at 0.84 ppm - must be at least 2.00 ppm. The salt system is down - CPO states he has ordered a replacement part and is installing it tomorrow (9/24/2024).

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

At time of inspection, the pH was observed to be 6.7 (pH must be 7.2 - 7.8). CPO already has the pool closed and will continue to balance water chemistry.

8 - chemical feeder operational and approved

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

At time of inspection, the salt system is not functioning. The CPO has ordered a replacement part and will install it tomorrow (9/24/2024).

Apr 2, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.