Kingsland, Camden County

Laurel Island Pool

110 MARSH HARBOUR PKWY KINGSLAND, GA 31548

Pool
Latest score
96
May 28, 2026
City
Kingsland
County
Camden
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 28, 2026

Permit/Opening

Score: 961 violation

13 - float line in position

Regulation: 511-3-5-.18(2) - (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of

4 ptsCorrected: NoRepeat: No

At time of inspection, the float line is missing from the pool. CPO states he has purchased the float line and will install it ASAP.

Oct 7, 2025

Routine

Score: 864 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

At time of inspection, the flow meter is stuck. CPO will repair/replace the flow meter.

13 - float line in position

Regulation: 511-3-5-.18(2) - (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of

4 ptsCorrected: NoRepeat: No

At time of inspection, two rope/float lines are needed where the slope begins from 3'-4' (the pool slopes from both ends from 3' to 6' in the middle of the pool). The anchors in the wall are in-tact, as well as the tile line. CPO will order the float/rope lines and install them ASAP.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) level registered at 109 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water, until CYA is below 90 ppm.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

At time of inspection, the marcite is chipping up in several areas. The marcite must be refinished before next pool season.

Apr 15, 2025

Permit/Opening

Score: 932 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

At time of inspection, the flow meter is not functioning (appears stuck). CPO will fix/replace the flow meter.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(b) - (b) warning signs for spas shall be in clear view of the spa and prominently displayed. signs shall state the spa's address, the location of the nearest telephone with references that emergency telephone numbers are posted at the location. these emer

2 ptsCorrected: NoRepeat: No

At time of inspection, the "Dial 9-1-1..." sign is missing from the area around the phone. CPO will acquire a sign and have it posted ASAP.

May 1, 2024

Permit/Opening

Score: 951 violation

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

At time of inspection, combined chlorine registered at 0.49 ppm (combined chlorine must be 0.4 ppm or less, or chlorine efficacy is diminished). CPO will drain some water and add fresh water.