St. Marys, Camden County

Cumberland Inn & Suites

2710 OSBORNE RD SAINT MARYS, GA 31558

Pool
Latest score
98
Apr 1, 2026
City
St. Marys
County
Camden
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 1, 2026

Permit/Opening

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

At time of inspection, no peak occupancy signage was present.// CPO will order

Oct 14, 2025

Routine

Score: 942 violations

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: Yes

At time of inspection, the cyanuric acid (CYA) level registered at 134 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water, to ensure that CYA is below 90 ppm.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

At time of inspection, the occupancy sign is missing. CPO will order the sign and install it ASAP.

Apr 17, 2025

Permit/Opening

Score: 942 violations

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid level registered at 171 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

At time of inspection, the "WARNING No lifeguard on duty..." sign is missing. CPO will order a sign and post it ASAP.

Sep 19, 2024

Routine

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time if inspection, the cyanuric acid level was above the maximum (must be 90 ppm or less). CPO will drain some water and add some fresh water to lower the stabilizer level.

Mar 12, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Mar 8, 2024

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

At time of inspection, emergency phone is not operational. After speaking with facility manager, learned that their whole facility was experiencing phone outages. Manager will contact Environmental Health Specialist (EHS), once the phone is operational and a re-inspection can be scheduled.