Feb 9, 2026
Routine
8 - annual gas fired equipment inspection on file; gas units equipped with automatic safety and/or 100% cut-off pilot
Regulation: 511-6-2-.15(5) - heating and fire safety-inspection
Facility does not have an annual gas fired equipment inspection on file.
RCA: All gas-fired equipment shall be inspected at least annually by a qualified licensed contractor or local fire authority, if available. Points to be inspected are proper construction and installation, malfunctions and adjustments of controls and burners, faulty heat exchangers and vent obstructions. Any defects found on inspection must be corrected by a qualified heating contractor prior to use of the equipment. Upon request, the operator shall provide evidence of inspection and/or correction of any deficiency
9 - food offered in compliance with tourist accommodation permit or food service permit; appropriate bed and breakfast or continental breakfast operations and menu; proper food temperatures; handwashing and no bare hand contact
Regulation: 511-6-2-.19(1) - food service establishment
Observed the facility food service to be operating in a capacity outside of the Tourist Accommodation Rules, and requires a permit per the State of Georgia Food Service Rules and Regulations, Chapter 511-6-1.
CA: PIC has submitted the required application and supporting documents to obtain a food service permit
31 - barrier adequate, gate locked, and installed properly; warning sign posted, procedures and log maintained
Regulation: 511-6-2-.16(2) - swimming pool barrier
Observed the outdoor pool facility to not have a complete barrier. Therefore, the pool is accessible at all times.
RCA: If a swimming pool or spa cannot comply with applicable regulations, then it must be enclosed with a fence at least four feet in height with a locked gate. In such case, guests shall not be allowed to use swimming pool or spa
30 - complies with all applicable regulations, permitted, approved operation
Regulation: 511-6-2-.16(1) - swimming pool in compliance with rules
Observed the pool associated with this facility to not be in compliance with current Pool Rules and Regulations, Chapter 511-3-5. Observed the pool to not be maintained and currently holds discolored water and an excess of debris. Observed exposed electrical wires from broken light fixtures. Observed large cracks in the pool deck.
RCA: Regulations of the Department and/ county in which govern the design, construction, operation and maintenance of swimming pools or spas shall apply to pools and spas operated in conjunction with a tourist accommodation