Mar 31, 2026
Permit/Opening
302 COCONUT DR BLOOMINGDALE, GA 31302
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Permit/Opening
Observed CH at 110.
RCA: CH shall be at 130 minimum.
Re-inspection
Routine
Regulation: .17((1)(c) - proper disinfectant level
Observed a free chlorine level of 1.2 ppm. RCA: Free Chlorine shall be between 2-10ppm.
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Observed a low cyanuric acid level of 8. RCA: CYA level shall between 10-90.
Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.
Observed handrail loose and removable without tools. RCA: Handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.
Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.
Observed chipped concrete throughout the deck.
CA: The deck where there is chipped concrete shall be repaired to be smooth.
RCA: The deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.
Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
Observed no bather load sign. RCA: A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
Observed the bottom of the pool surface to not be smooth throughout the entire pool in various locations.
CA: The pool shall be drained and resurfaced to be smooth throughout the entire pool.
RCA: Pools shall be constructed of reinforced concrete or impervious and structurally sound materials, which provide a smooth, easily cleaned, watertight structure capable of withstanding the anticipated loads for full and empty conditions, taking into account climatic and hydrostatic considerations, and the integration of the pool with other structures.
Observed seats in the shallow side of the pool. RCA: The seats shall be removed from the shallow side of the pool.
Permit/Opening