Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed pH above 7.8. Advised to adjust
Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type
Observed pool not meeting adequate turnover rate. Advised to adjust
Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.
Observed pool deck with no universal no diving symbol and no diving not in 4 inch lettering. Advised to install
Re-inspection
Re-inspection
Regulation: .17((1)(c) - proper disinfectant level
Observed pool chlorine too low. Advised to raise to 2.0 to 10.0 chlorine.
Need longer throw rope attached to life saving buoy. Advised it shall be 50 foot or the width and the half of the pool whichever is less.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Observed 2 weirs missing. Advised to replace.
Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.
Observed missing end cap on ladder at time of inspection. Advised CPO to replace.
Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.
Observed no soap in restrooms. COS: PIC placed soap in restrooms.
Regulation: 511-3-5-.19(1)(e ) - (e) hot and cold water under pressure shall be provided in dressing facility showers.
Observed showers in men's and women's restrooms not working.
Permit/Opening
Regulation: .10(5) - compliant drain cover
Need main drain cover certification letter.
Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e
Water too cloudy to clearly see main drains at bottom of pool.
Regulation: .17((1)(c) - proper disinfectant level
Observed pool chlorine too low. Advised to raise to 2.0 to 10.0 chlorine.
Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.
Could not observe pumps working. Pumps not on at time of inspection.
Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch
Throw rope frayed, tangled, and in disrepair. Advised to replace.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter not working. CNO proper flow.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Observed 3 missing weirs. Advised to replace.
Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.
Observed missing end cap on ladder at time of inspection. Advised CPO to replace.
Regulation: 511-3-5-.18(13)(b) - (b) warning signs for spas shall be in clear view of the spa and prominently displayed. signs shall state the spa's address, the location of the nearest telephone with references that emergency telephone numbers are posted at the location. these emer
Observed address not posted next to emergency phone. Advised to post.
Regulation: 511-3-5-.19(2)(n) - (n) sanitary facility fixtures and dressing area fixtures and furniture shall be cleaned and sanitized with an epa-approved product and as needed to provide a clean and sanitary environment.
Observed both men's and women's bathroom in need of cleaning. Advised to clean.
Regulation: 511-3-5-.19(2)(h) - (h) toilet paper holders shall be provided at each water closet.
Observed no toilet paper in bathrooms.
Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.
Observed no soap and paper towels in restrooms.
Regulation: 511-3-5-.19(1)(e ) - (e) hot and cold water under pressure shall be provided in dressing facility showers.
Observed deck shower not operational.
Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.
Observed piping and direction of flow not marked. Advised to mark.
Re-inspection
Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis
Observed missing pool occupancy sign near entrance of the pool. Advised CPO that a theoretical occupancy sign shall be placed at the entrance of the pool deck.
Observed lifeguard on duty sign with missing portion stating "supervise children closely. Advised PIC/CPO that a no lifeguard on duty/supervise children sign in 4" letters shall be placed in clear view.
Permit/Opening
Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
Observed flow meter in disrepair and could not determine turnover rate during the time of inspection. Advised PIC/CPO that a flow meter shall be in good repair in order to determine adequate turnover rate. CA: Advised CPO/PIC to replace flow meter.
Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.
Observed loose handrails and missing end caps at time of inspection. Advised CPO to repair.
Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis
Observed lifeguard on duty sign with missing portion stating "supervise children closely. Advised PIC/CPO that a no lifeguard on duty/supervise children sign in 4" letters shall be placed in clear view.