Lake City, Clayton County

The Flats at 1885

1885 HARPER RD LAKE CITY, GA 30260

Pool
Latest score
80
Jun 24, 2025
City
Lake City
County
Clayton
Inspections
3

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 24, 2025

Permit/Opening

Score: 804 violations

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: YesRepeat: No

Observed throwing rope for ring buoy not meeting length requirements. Advised PIC A minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inches. COS: CPO placed a longer throwing rope for ring buoy during time of inspection.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

2 ptsCorrected: NoRepeat: No

Observed multiple cracks present on the deck area during time of inspection. Advised PIC that the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter. Advised PIC/CPO to repair crack on deck.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: YesRepeat: No

Upon arrival, observed peak occupancy sign located near the entrance of the pool. Advised PIC that a theoretical peak occupancy sign shall be posted near the entrance of the pool. COS: PIC placed a maximum peak occupancy sign near the entrance of the pool.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed pool interior in need of resurfacing during time of inspection. Advised PIC that the interior of the pool shall be smooth. Advised PIC to resurface the pool prior to opening for the season.

Jun 21, 2024

Permit/Opening

Score: 963 violations

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

2 ptsCorrected: NoRepeat: No

Cracks present in deck in multiple areas, in need of repair. Deck shall be properly maintained

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: Yes

Observed missing :no diving: universal tile around pool deck area. Advised PIC/CPO that universal no diving tiling shall be installed on deck 18 inches from pool edge in water less than or equal to 5'. CA: Advised CPO to install universal "no diving: tiling around pool deck.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Pool occupancy sign not posted. Pool capacity sign posted is not compliant

Jun 23, 2023

Permit/Opening

Score: 963 violations

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed loose handrail near 9 ft. marker. Also observed missing end caps on railing near 5 ft. marker. Advised PIC/CPO that grab rails, handrails. and ladders shall not be removed without the use of a tool. Advised PIC/CPO to tighten handrail near 9 ft. marker. Advised PIC/CPO to install end caps on handrail near 5 ft. marker.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Observed missing :no diving: universal tile around pool deck area. Advised PIC/CPO that universal no diving tiling shall be installed on deck 18 inches from pool edge in water less than or equal to 5'. CA: Advised CPO to install universal "no diving: tiling around pool deck.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed missing peak occupancy sing and hours of operation sign on entrance. Advised CPO/PIC that a sign stating the hours of operation and theoretical peak occupancy shall be placed near entrance of pool deck.