MARIETTA, Cobb County

HAMPTONS AT EAST COBB THE - WADE

1523 ROSWELL RD MARIETTA, GA 30062

Pool
Latest score
84
May 14, 2026
City
MARIETTA
County
Cobb
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 14, 2026

Re-inspection

Score: 843 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: Yes

Chlorine observed at 20++ (EHS titrated and the solution became darker with more drops added)

C/A: chlorine shall be maintained between 2-10ppm

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: Yes

Observed pH less than 7.0

C/A: maintain pH between 7.2 to 7.8

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(e ) - (e) soap dispensers for providing either liquid or powdered soap shall be provided at each lavatory. the dispenser shall be of all metal or plastic. no glass shall be permitted in these units.

1 ptsCorrected: NoRepeat: No

Observed no soap in either bathroom

C/A: provide soap

Apr 30, 2026

Permit/Opening

Score: 834 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Chlorine observed at 20++ (EHS titrated and the solution became darker with more drops added)

C/A: chlorine shall be maintained between 2-10ppm

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH less than 7.0

C/A: maintain pH between 7.2 to 7.8

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.

15 ptsCorrected: NoRepeat: No

Observed body hook not attached to 12ft pole

C/A: firmly attach body hook to non-telescoping 12ft pole

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: YesRepeat: No

Observed no "pool risk" signage with the 10 statements

C/A: provide signage

COS: sign provided

Aug 5, 2025

Permit/Opening

Score: 807 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone (kings 3 box) did not call out to 911; EHS waited for 7 minutes

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Chlorine observed at 20++ (EHS titrated and the solution became darker with more drops added)

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

Observed pH at 7.0

8 - chemical feeder operational and approved

Regulation: 511-3-5-.16(2)(a) - (a) every pool and spa shall be required to have at least one unit of disinfectant agent equipment that introduces the agent through the circulation system in compliance with this rule

15 ptsCorrected: NoRepeat: No

Observed chlorine tablets in the skimmers

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.

15 ptsCorrected: NoRepeat: No

Observed no body hook; CPO later found it the pump room but had no pole to attach it to

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

Facility unable to provide CPO certification

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.

1 ptsCorrected: NoRepeat: No

No toilet paper or soap in women's bathroom and women's bathroom had a hole in the wall

Aug 22, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.