Mar 20, 2026
Re-inspection
6 - proper disinfectant level
Observed chlorine at 12ppm.
C/A: maintain free chlorine levels at 2-10ppm; ideal 3-5ppm.
2800 HIGHLANDS PKWY SE SMYRNA, GA 30082-5114
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Re-inspection
Observed chlorine at 12ppm.
C/A: maintain free chlorine levels at 2-10ppm; ideal 3-5ppm.
Routine
Regulation: .17((1)(c) - proper disinfectant level
Observed chlorine level at 1ppm.
C/A: maintain free chlorine levels at 2-10ppm; ideal 3-5ppm.
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed pH below 7.0.
C/A: pH levels shall be maintained between 7.2-7.8; ideal 7.4-7.6.
Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.
Observed broken ladder rung.
C/A: Ladders shall be maintained and secure.
Re-inspection
Routine
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
Recorded pH of 7.0. Needs to be between 7.2 and 7.8.
CA: raise and maintain pH to 7.2-7.8.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Flowmeter inoperable / out of order.
CA: A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided.
Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
There was no log / record keeping documentation for pool chemicals.
CA: Self-inspections should be documented on a log/record sheet.
Routine
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter not operating.
CA: Fix flow meter
Re-inspection
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter not operating.
CA: Fix flow meter
Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.
Pressure gauge is stuck.
CA: Fix pressure gauge.
Routine
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
pH observed at a 7.0, maintain at a 7.2-7.8
Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.
Filter was not running during inspection
Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.
Pump was not running during inspection
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Skimmers missing weirs, water level too low
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
CPO expired 04/23/24
Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.
Ladder rung broken
Routine