Vinings, Cobb County

COURTYARD BY MARRIOTT - POOL

2829 OVERLOOK PKWY ATLANTA, GA 30339

Pool
Latest score
98
Feb 2, 2026
City
Vinings
County
Cobb
Inspections
10

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Feb 2, 2026

Routine

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed loose handrails along the pool by 5ft depth markers. C/A: Hand/grab rails must be secured and installed correctly.

Jun 24, 2025

Re-inspection

Score: 913 violations

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: Yes

Install a weir in skimmer by patio door.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

Replace cover over return inlet.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

Replace the missing tile inside the pool.

Jun 20, 2025

Re-inspection

Score: 803 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

The chlorine tested high. Levels must test between 3-10 ppm.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

The cyanuric acid tested high. Must test between 0-90.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Replace the missing tile inside the pool.

Jun 18, 2025

Routine

Score: 774 violations

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

The Cl tested at 1 ppm. Cl must test between 3-10 ppm.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

The pH tested at 7.0. The pH must test between 7.2- 7.8.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: Yes

Provide inlet covers on the return line.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

The cyanuric acid tested above 100. The cyanuric acid must test between 0-90.

Mar 19, 2025

Routine

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Tighten the handrail near the 5ft depth marker. Straighten the first step of the stairs on the handrail closest to the gym.

Aug 14, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 5, 2024

Routine

Score: 942 violations

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Weirs missing from skimmers, water level observed was low

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: Yes

Rail extends out of the ground. Fix ASAP

Apr 11, 2024

Routine

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: Yes

Tighten the handrails near the 5 ft depth marker. Employees are working on the handrail.

Aug 17, 2023

Routine

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Tighten the handrails near the 5 ft depth marker. The handrail will not completely come out of the ground but it is loose. The pool is ok to remain open.

Jun 14, 2023

Routine

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed hand rails around pool loose; need to tighten handrails