Permit/Opening
106 BAILEY STATION CT SHARPSBURG, GA 30277
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
Regulation: 511-3-5-.18(18) - (18) class c multi-family residential housing pools are exempt from the requirements of (17) and (18) of the rule, if the facility is only open to residents and their guests.
Observed no deck shower.
Permit/Opening
Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.
Observed no deck shower.
Routine
No deck shower
Permit/Opening
Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:
Observed no "Pool risks" sign posted.
Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis
Observed no Lifeguard sign posted.
Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.
No deck shower
Routine
Regulation: .17((1)(c) - proper disinfectant level
Observed chlorine too high at 17.5 ppm.
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
Observed pH at 8.0 or above.
Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type
Observed flow meter at 20 gpm which is below the minimum of 42 gpm required for a 30 minute turnover rate. The flow meter may be broken.
Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:
Written documentation was not provided showing CPO had visited/tested the pool twice a week.
Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
Observed peak occupancy listed too high. Should only be 30.
Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:
Sign was missing some of the rules and did not properly state the 2 week minimum required before swimming after diarrhea.
Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.
No deck shower
Calcium hardness was below minimum at 140 ppm. Total alkalinity could not be tested due to chlorine levels being too high.
Permit/Opening
Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:
No sign with Pool Rules. No sign stating peak occupancy.
Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.
No deck shower