DAWSONVILLE, Dawson County

ONELIFE FITNESS - POOL

534 MARKETPLACE PKWY STE 200 DAWSONVILLE, GA 30534

Pool
Latest score
90
Nov 6, 2025
City
DAWSONVILLE
County
Dawson
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Nov 6, 2025

Re-inspection

Score: 902 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: Yes

Combined chlorine level shall be 0.4 ppm or less. Level today was 1.0 ppm. Informed CPO. Provided documents outlining how to appropriately fix this issue.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type

5 ptsCorrected: YesRepeat: Yes

The turnover rate for the pool "shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less"

Flowmeter reading should read a minimum of 163 gpm. Today's reading was 150 gpm, which is not high enough to keep a 6 hour turnover rate. Informed the CPO and he adjusted.

Oct 7, 2025

Complaint

Score: 629 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

The chlorine level of the pool shall be a minimum of 1.0 ppm and a maximum of 10 ppm. Today's reading is <1.0 ppm. Informed PIC.

18 - combined chlorine level 0.4 ppm or less

5 ptsCorrected: NoRepeat: Yes

Combined chlorine level shall be 0.4 ppm or less. Level today was 1.0 ppm. Informed PIC

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

The turnover rate for the pool "shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less"

Based on a flowmeter reading of 90 gpm, >10 hours would be required for the full turnover rate of this pool. Informed PIC

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: Yes

Daily recordkeeping is required for pH and Chlorine. None found for any recent months. Log book unorganized and not updated regularly. Informed PIC readings must be taken twice daily.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: Yes

No weirs present in the pool. Informed PIC.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: Yes

Both ladders on the back side of the pool have loose handrails. Informed PIC.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(n) - (n) sanitary facility fixtures and dressing area fixtures and furniture shall be cleaned and sanitized with an epa-approved product and as needed to provide a clean and sanitary environment.

1 ptsCorrected: NoRepeat: No

Restroom had paper and debris all over the floor. Informed PIC

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

511-3-5-.22(1) All swimming pools and spas covered by this Chapter shall be maintained under the supervision and direction of a properly trained operator who shall be responsible for the sanitation, safety, and proper maintenance of the pool and all related equipment, and for the daily recordkeeping. Pump room as a significant leak coming from the piping. Informed the PIC.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

511-3-5-.17 Calcium hardness shall be between 150-1000 ppm. Today's level was 140 ppm.

Jul 14, 2025

Routine

Score: 863 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

The turnover rate for the pool "shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less"

Based on a flowmeter reading of 110 gpm, >8 hours would be required for the full turnover rate of this pool. Informed PIC

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Daily recordkeeping is required for pH and Chlorine. None found for any recent months. Log book unorganized and not updated regularly.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

Only a few CPO records present (from January 2025). Informed the new PIC that this is required for every visit from CPO.

Jan 15, 2025

Complaint

Score: 902 violations

18 - combined chlorine level 0.4 ppm or less

5 ptsCorrected: NoRepeat: Yes

Combined chlorine level shall be 0.4 ppm or less. Level today was 2.71 ppm. Informed PIC

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

The turnover rate for the pool "shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less"

Based on a flowmeter reading of 110 gpm, 9 hours would be required for the full turnover rate of this pool. Informed PIC

Dec 6, 2024

Routine

Score: 883 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: Yes

Combined chlorine level shall be 0.4 ppm or less. Level today was 2.86 ppm. Informed PIC

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

The turnover rate for the pool "shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less"

Based on a flowmeter reading of 110 gpm, 9 hours would be required for the full turnover rate of this pool. Informed PIC

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: Yes

Hand railings wobbly. Informed PIC

Aug 30, 2024

Complaint

Score: 844 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Combined chlorine level shall be 0.4 ppm or less. Level today was 2.41 ppm

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Pool flow meter coated with residue and non functioning. Informed PIC

35 - operator facility inspections performed; written documentation

4 ptsCorrected: NoRepeat: Yes

No CPO records present at facility. PIC contacting corporate to get GM access to records on property

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: Yes

Hand railing loose at end of pool closest to spa. CPO to secure

May 9, 2024

Routine

Score: 914 violations

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

CPO water testing recordings not found.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Hand railing loose at end of pool closest to spa. PIC to secure

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: Yes

No hours of operation or peak occupancy posted for pool.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

511-3-5-.22(1) All swimming pools and spas covered by this Chapter shall be maintained under the supervision and direction of a properly trained operator who shall be responsible for the sanitation, safety, and proper maintenance of the pool and all related equipment, and for the daily recordkeeping. Pump room as a significant leak coming from the piping. Informed the PIC.

Dec 15, 2023

Routine

Score: 735 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone present but with no dial tone.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: Yes

The flow meter is not working. Informed PIC. Repeat violation.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

No weirs present in pool.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed hours of operation posted on entry to pool, but sign does not have peak occupancy noted.

34 - inspection report placed in public view

Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

1 ptsCorrected: YesRepeat: No

Inspection report in a non-public location.