ATLANTA, DeKalb County

BRIARMOOR MANOR RECREATION CLUB (POOL)

2682 CALADIUM DR ATLANTA, GA 30345

Pool
Latest score
91
Jun 12, 2026
City
ATLANTA
County
DeKalb
Inspections
9

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 12, 2026

Routine

Score: 912 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: Yes

Needs to maintain at least 430 gpm, but it was at 400 gpm.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: Yes

Skimmers were operational but not maintained.

Apr 28, 2026

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-198(b) Ready access, suitable drainage (such as a sump pump) and ventilation of fresh make-up air must be provided for all equipment rooms. The enclosure must be ventilated with outside air by a chlorine-resistant exhaust fan with vents that are located a maximum of four inches (4”) above the floor level, equipped with automatic louvers to achieve cross-flow ventilation located at the top of the enclosure for admitting fresh air, and capable of providing one (1) enclosure air change every three (3) minutes. The exhaust fan shall be installed so as to exhaust the equipment room air away from the pool enclosure and adjacent inhabited areas.

Jun 10, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Apr 29, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 11, 2024

Routine

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5): All pools shall be kept free from sediment, dirt, or debris by frequently brushing and vacuuming the bottom and sidewalls. Observed debris at the bottom of pool.

Jun 12, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Apr 26, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 26, 2023

Routine

Score: 745 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: YesRepeat: No

13-189(C)(1) - POOL SHALL BE MAINTAINED WITH A PH LEVEL BETWEEN 7.2 - 7.8

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(D)(2) - PERMANENT "NO DIVING" MARKERS MUST BE IN MINIMUM TWO INCH BLACK LETTERS WITH WHITE BACKGROUND. OBSERVED "NO DIVING" MARKERS ONE INCH HIGH

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196(A)(4) - EACH SKIMMER SHALL HAVE A PROPERLY DESIGNED AND OPERATING WEIR. OBSERVED SKIMMERS WITH NO WEIR

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

13-184(E)(5) - UNSECURED STEPS/HANDRAILS CONSIDERED AN IMMINENT HEALTH HAZARD. OBSERVED CRACK STEPS BY ONE OF THE HANDRAILS

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-200(A) - NIGHT LIGHTING ADEQUATE AND IN GOOD REPAIR. OBSERVED ONE LIGHT IN NEED OF REPAIR

Jun 13, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.