Routine
13-202(g): An hard-wired, operable telephone with 911 capability shall be made available within the pool area. Observed emergency was not operational.
13-190(a) The equipment shall be operated continuously to obtain a minimum turnover rate of 69 gpm, the observed turnover rate was 60 gpm.
13-189(c)(4): The pool water shall be tested for chlorine and pH at least 2x/day. Observed empty test logs.
13-201(k): A minimum of 1 diaper changing station shall be provided in each men's and women's bathrooms. No diaper changing stations were observed. No imminent health hazards observed in restrooms.
13-189(b): Approved backflow prevention shall be provided on all lines. Observed hose submerged in pool. Corrected on site.
Permit/Opening
Permit/Opening
Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e
511-3-5-.07(1)(e ) - (e) Water clarity shall be maintained. When standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. Water clarity shall be maintained. When standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. Observed cloudy water in the pool upon arrival for inspection.
Regulation: .17(1)(a)(b) - proper disinfectant level
(a) Free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.(b) All public pools except as listed below: Minimum 1.0 Ideal 1.0-3.0 Maximum 10.0 Observed FCL reading at 0.80 ppm and then again at 2.89 ppm
Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch
A minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch. Observed foam ring buoy with rope that was not US Coast Guard approved.
Routine
13-190(a) The equipment shall be operated continuously to obtain a minimum turnover rate of 69 GPM, the observed turnover rate was 62 GPM.
13-202(m): Safety rules' sign lettering shall be a minimum of 3/4 inches tall unless otherwise noted. "NO SOLO BATHING" and "CHILDREN MUST BE ACCOMPANIED BY AN ADULT" must be 2 inches high. "WARNING-NO LIFEGUARD ON DUTY" must be 4 inches high.
13-201(k): A minimum of 1 diaper changing station shall be provided in each men's and women's bathrooms. No diaper changing stations were observed.
Permit/Opening
13-202(m): safety rules and regulations shall be easily readable and shall be conspicuously posted in the pool area. Observed facility missing the following signs that shall be placed in the pool area: "No food or Drink Allowed within 5 feet of the pool" "Bathers with open wounds, skin conditions, or any communicable condition not allowed" "Bathers Shall wear bathing attire" "No spitting, spouting, blowing nose, or any bodily excretion allowed"
Permit/Opening
13-189(c)(4) The pool water shall be tested for disinfectant level and pH at least twice each day.
Permit/Opening
13-189(c)(1) The free chlorine residual shall be maintained in all parts of the pool at a concentration of between 3-10ppm, observed chlorine was 0.38ppm at inspection.
13-190(a) The equipment shall be operated continuously to obtain a minimum turnover rate of 69gpm, the observed turnover rate was 50gpm.
13-189(c)(2) Cyanuric acid levels shall not exceed 100ppm. Observed reading was 208plus at inspection.