Jun 3, 2026
Routine
36 - daily recordkeeping: water testing and self inspection performed
13-189(c)(4): Pool water shall be tested twice daily for disinfectant level and pH. No daily logs available for this pool.
1468 BRIARWOOD RD ATLANTA, GA 30319
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Routine
13-189(c)(4): Pool water shall be tested twice daily for disinfectant level and pH. No daily logs available for this pool.
Permit/Opening
Routine
13-202(l): float line must be present and installed to separate swimming areas where depths exceed 5 ft.
Observation: Float line was present but not installed; called the CPO and they were able to come and fix it by reinstalling it.
13-201(c)(3): Bathroom sinks shall provide hot water.
Observation: No hot water in bathroom sinks.
13-201(b): Deck rinses should provide hot water with a range of 70-104 degrees Fahrenheit.
Observation: Deck rinse does not have hot water.
Permit/Opening
Routine
13-190(a) Equipment shall be operated continuously on a twenty four hour basis to obtain the minimum required number of four turnovers each day. Observed that pool flow meter was at 80 gpm however for a pool this size at 52000 g the required turnover rate is 144 gpm.
13-189(c)(4) Pool water shall be tested for the disinfectant level and pH at least twice each day including prior to opening and during peak bathing loads. Observed that daily pool log indicated that the pool was being tested two times weekly.
13-202(m) Rules must contain at a minimum the 12 statements required in pool code. Observed that pool rules signage was missing information for operational hours.
13-187(c) Current inspection report shall be displayed in a conspicuous place, easily readable by the public at all times upon entry into pool area. Observed that inspection report from last summer posted in pool area; Current inspection missing.
13-187(c) Operating permit shall be framed and displayed in conspicuous place as close to the pool entrance as possible such that it is easily readable by the public at all times. Observed that current operating permit missing; Last year's permit posted on display.
Routine
13-190(a): Equipment shall be operated continuously on a twenty four hour basis to obtain the minimum required number of four turnovers each day. Observed that pool flow meter was at 130 gpm however for a pool this size at 52000 g the required turnover rate is 144 gpm.
13-189(c)(4): Pool water shall be tested for the disinfectant level and pH at least twice each day including prior to opening and during peak bathing loads. Observed that pool testing log did not indicate pool was being tested two times daily.
13-202(m): Rules must contain at a minimum the 12 statements required in pool code. Observed that pool was missing information for operational hours on pool rules signage.
Permit/Opening
Routine
13-189(c)(1): The free-chlorine residual in all parts of the pool shall be maintained between 3-10 ppm at all times. Observed flow meter maxed at 140 gpm. For a 52,000 g pool, the flow rate shall be greater than 144 gpm. An appropriate flow meter range is 1.5x the minimum required flow rate.
13-190(a)(7): An adequately sized flow meter shall be installed on the return line. Observed flow meter with small range. Pool with volume 52,000 gallons should have a flow rate greater than 144 gpm.
13-189(c)(4): The pool shall be tested for disinfectant level and pH at least 2 times per day. Observed logs testing most days, once per day.
Re-inspection
13-190(a)(7): An adequately sized flow meter shall be installed on the return line. Observed flow meter with small range. Pool with volume 52,000 gallons should have a flow rate greater than 144 gpm.
13-189(c)(4): The pool shall be tested for disinfectant level and pH at least 2 times per day. Observed logs testing every other day, once per day.
13-201(c)(3): Lavatory with tempered water with a temperature range of 70 - 104 degrees F shall be provided. Observed sinks with no hot water.
Routine
13-197(b&c): Timers used in conjunction with feeders are not allowed. Observed timer set to "Auto".
13-202(d): Lifesaving equipment shall be mounted in a conspicuous place and be readily available for use. Observed buoy hanging on outer side of pool enclosure.
13-190(a)(7): An adequately sized flow meter shall be installed on the return line. Observed flow meter with small range- unable to determine actual flow rate.
13-189(c)(4): The pool shall be tested for disinfectant level and pH at least 2 times per day. Observed logs missing days and testing once per day.
13-201(c)(3): Lavatory with tempered water with a temperature range of 70 - 104 degrees F shall be provided. Observed sinks with no hot water.