Brookhaven, DeKalb County

ASHFORD LAKE CONDOMINIUMS

3900 ASHFORD LAKE CT ATLANTA, GA 30319

Pool
Latest score
100
Jul 17, 2025
City
Brookhaven
County
DeKalb
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jul 17, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 14, 2024

Routine

Score: 933 violations

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4) Pool water shall be tested for disinfectant and pH at least twice each day or as often as needed including prior to open and during peak bathing loads. Observed that daily pool log indicated that pool was being tested twice weekly.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c) Current inspection report shall be displayed in a conspicuous place where it is easily readable by the public at all times. Observed that recent inspection report was not available on site.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-187(c) Operating permit shall be framed and displayed close to entrance as possible such that it is easily readable by the public at all times. Observed that this year's operating permit was not posted in the pool area.

Jun 24, 2024

Routine

Score: 933 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): Equipment shall be operated on a twenty four hour basis to obtain the minimum required number of four turnovers per day. Observed that flow meter was stuck at 0 gpm and must maintain at 75 gpm for adequate turnover.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: Yes

13-201(b): A shower with tempered water with a temperature range of 70 to 104 degrees Fahrenheit shall be provided at each approved entrance into the pool area. Observed deck shower was not operational.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-198(a): Entry door shall open to the exterior of the equipment room or enclosure and shall be kept locked except for when servicing the pool equipment. Observed that door into equipment room was unlocked upon arrival.

May 17, 2024

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

I observed deck shower not working due to a leak.

Jul 24, 2023

Re-inspection

Score: 943 violations

32 - operator training certification available onsite and approved

4 ptsCorrected: NoRepeat: No

13-187(c): A copy of the pool operator's certificate shall be conspicuously displayed near the operating permit. Could not locate.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: Yes

13-201(b): A shower with tempered water shall be provided at each approved entrance into the pool area. Observed cracked deck shower with no water. Repeat violation.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

13-202(i): Each pool facility shall have a written copy of the Emergency Action Plan (EAP) located to allow for immediate access in case of emergency. Could not locate.

13-197(k): All pools shall have have adequate, safe, and secure storage of pool chemicals. Observed pool chemicals on the floor of the pump room. Must be moved to shelf/pallet

Jul 24, 2023

Routine

Score: 894 violations

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: Yes

13-189(c)(4): The pool water shall be tested for disinfectant and pH at least 2 times daily. Could not locate test log.

13 - float line in position

4 ptsCorrected: NoRepeat: No

13-202(l): Tightly stretched float line shall be installed across pool where depths exceed 5 feet. A 4" non-slip tile must be installed directly beneath and for the entire length of each float line. Observed float line detached and falling apart on the pool deck. Non-slip tile was not present.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: Yes

13-201(b): A shower with tempered water shall be provided at each approved entrance into the pool area. Observed cracked deck shower with no water. Repeat violation.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(i): Each pool facility shall have a written copy of the Emergency Action Plan (EAP) located to allow for immediate access in case of an emergency. Could not locate EAP.

Jun 27, 2023

Routine

Score: 933 violations

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4): Pool water shall be tested for disinfectant and pH at least 2 times daily. Observed log testing twice weekly.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201(b): A shower with tempered water with a temperature range between 70F - 104F shall be provided at each approved entrance into the pool area. Observed deck shower broken with no water.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c): The current inspection report shall be placed in a conspicuous place where it is easily readable from the pool area. Inspection report was placed in the equipment shed.

May 17, 2023

Permit/Opening

Score: 991 violation

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201(b) Deck shower pipe cracked and not functional. Please repair this as soon as possible.