Chamblee, DeKalb County

ANDERSON AT CLAIRMONT APARTMENTS

2500 NORTHEAST EXPRESSWAY ATLANTA, GA 30345

Pool
Latest score
85
Aug 19, 2025
City
Chamblee
County
DeKalb
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Aug 19, 2025

Permit/Opening

Score: 852 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

Emergency phone goes to 911 but the operator does not have the address on file or a valid phone number

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

FCL observed at 0.52 and raised to 5.06

Jul 31, 2025

Permit/Opening

Score: 786 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

Emergency phone went directly to kings three and could not go out to 911

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

disinfectant level below 3ppm at 0.06ppm

32 - operator training certification available onsite and approved

4 ptsCorrected: NoRepeat: No

Operator certification not posted near pool area

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

Men's bathroom was not stocked with soap and toilet paper.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

Previous inspections not in view

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

No valid permit issued.

Jun 4, 2025

Permit/Opening

Score: 803 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

pH level was not in adequate range. 1st pH reading: 6.7, 2nd: 7.0, 3rd reading 6.3.

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: No

Ring buoy was not Coast Guard approved.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Flow meter was not in adequate range. GPM was reading 40, maximum should have been 138 or better.

Jul 1, 2024

Re-inspection

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The equipment shall be operated continuously on a 24-hour basis to obtain a minimum of 4 turnovers per day. Observed flow meter at 40 gpm, should be at least 139 gpm.

Jun 18, 2024

Routine

Score: 794 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The free chlorine residual in all parts of the pool shall be maintained at a concentration of no less than 3 ppm and shall not exceed 10 ppm. Observed pool at 0.05 ppm and again at 0.08 ppm.

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: No

13-202(d): Each pool shall be provided with a Coast Guard approved life saving ring with a throwing rope. Observed Coast Guard approved ring with no rope attached.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

13-190(A) EQUIPMENT MUST OBTAIN MINIMUM OF ONE TURNOVER EVERY 6 HOURS. MINIMUM GPM ON FLOWMETER SHOULD READ ~139 GPM. FLOWMETER AT THE TIME OF INSPECTION READ 35 GPM

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-184(e)(5): Imminent Health Hazards exists if the sanitary facilities are not functional or maintained in a clean and sanitary condition. Observed female restroom with no soap or tissue. In addition, floor was covered in urine and wet tissue, making it slippery.

May 24, 2024

Permit/Opening

Score: 942 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(A) EQUIPMENT MUST OBTAIN MINIMUM OF ONE TURNOVER EVERY 6 HOURS. MINIMUM GPM ON FLOWMETER SHOULD READ ~140 GPM. FLOWMETER AT THE TIME OF INSPECTION READ 50 GPM

37 - other violations of the chapter

1 ptsCorrected: YesRepeat: No

13-202(K) FIRST AID KIT MUST BE MOUNTED IN CONSPICUOUS LOCATION IN THE POOL AREA. FIRST AID KIT WAS NOT AVAILABLE UPON INSPECTION

Jul 27, 2023

Routine

Score: 894 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(A) EQUIPMENT MUST OBTAIN MINIMUM OF ONE TURNOVER EVERY 6 HOURS. MINIMUM GPM ON FLOWMETER SHOULD READ ~140 GPM. FLOWMETER AT THE TIME OF INSPECTION READ 55 GPM

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196(A)(4) - EACH SKIMMER SHALL HAVE A PROPERLY DESIGNED AND OPERATING WEIR. OBSERVED SKIMMER WITHOUT WEIR

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(J) - ADEQUATELY SIZED COVERED AND LINE RECEPTACLE SHALL BE PROVIDED IN EACH MEN AND WOMEN'S BATHROOM. OBSERVED BATHROOMS WITH NO TOILER PAPER AND GARBAGE BINS NOT LINED

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(I) - EACH POOL FACILITY SHALL HAVE IN PLACE A DEPARTMENTALLY APPROVED EMERGENCY ACTION PLAN

Jun 27, 2023

Permit/Opening

Score: 942 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(A) EQUIPMENT MUST OBTAIN MINIMUM OF ONE TURNOVER EVERY 6 HOURS. MINIMUM GPM ON FLOWMETER SHOULD REAL 138. FLOWMETER AT THE TIME OF INSPECTION READ 50 GPM

37 - other violations of the chapter

1 ptsCorrected: YesRepeat: No

13-202(K) FIRST AID KIT MUST BE MOUNTED IN CONSPICUOUS LOCATION IN THE POOL AREA. FIRST AID KIT WAS NOT AVAILABLE UPON INSPECTION