Jun 10, 2026
Routine
5565 MILL TRACE DR DUNWOODY, GA 30338
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Routine
Permit/Opening
Permit/Opening
13-189(c)(2): Cyanuric acid levels shall not exceed 100gpm. Observed kiddie pool cyanuric acid level at 156ppm.
13-198(a) Observed kiddie equipment pump area with enclosure heavily damaged and unable to restrict unauthorized access to pool equipment.
13-198(a) Observed kiddie equipment pump area with enclosure heavily damaged and unable to restrict unauthorized access to pool equipment.
Routine
13-189(c)(1) Only chlorine can be used as primary means of disinfectant
Routine
Routine
13-202(a)(2): Entry into the pool area shall be a self-closing, self-latching gate.
13-197(i) No disinfectant added by hand as the sole primary method of adding disinfectant or pH control.
13-202(e): Code says lifeguard certifications must be available on site.
13-196(a)(4): Code says skimmer must have an operable weir
Permit/Opening
Routine
Routine
Permit/Opening
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter was not functioning at the time of inspection. Discussed with the person in charge that flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.
Routine
13-196(a)(4): Code says skimmer must have an operable weir -Observed no operable weir
13-201(k): Code says trashcans must have lids -Observed no lid in men's room
13-187(c): Code says last inspection must be placed in public view -Observed no inspection
Routine
13-196(a)(4): Code says skimmer must have an operable weir -Observed no operable weir
Routine
13-196(a)(4): Code says skimmer must have an operable weir -Observed no operable weir
13-187(c): Code says last inspection must be placed in public view -Observed no inspeciton