Aug 5, 2025

Routine

Score: 843 violations

4 - water clarity: main drains clearly visible

15 ptsCorrected: NoRepeat: No

13-189(c)(6) At all times a pool is in used the water shall be of such clarity that the main drains on the bottom of the pool at the deepest point are clearly visible from the deck. I was not able to see the drains at the botom of the pool. Pool is very cloudy.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1) The pool shall be maintained in an alkaline condition at all times with pH levels between 7.2-7.8. pH first reading was 6.9; 2nd test produced a 8.6 value.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5) All pools shall be kept free from sediment dirt, or debris. Observed sediment at the bottom of the pool before the water turned cloudy.

Jun 2, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 30, 2025

Permit/Opening

Score: 851 violation

4 - water clarity: main drains clearly visible

15 ptsCorrected: NoRepeat: No

13-189(c)(6) At all times when pool is in use, the water shall be of such clarity that the main drains on the bottom of the pool at the deepest point are clearly visible from the deck. The viewer shall be able to to clearly distinguish the the type, shape and number of openings of the main drain grates or covers. While inspecting the pool, I was unable to see the bottom of the pool. I could not see the drains, and drains covers.

Aug 7, 2024

Routine

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: YesRepeat: Yes

Cyanuric acid level at maximum 100ppm, but very high. Recommend backwashing.

Aug 6, 2024

Routine

Score: 812 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Free chlorine was not in proper range. Code says Chlorine must be between 3-10ppm. First measurement: 0.22 Second measurement: 0.23

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

Cyanuric acid was measured at 170+. Code says cyanuric acid must not exceed maximum 100ppm.

Jun 18, 2024

Permit/Opening

Score: 982 violations

30 - deck/rinse shower maintained

Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.

1 ptsCorrected: YesRepeat: No

13-201(b); Code says deck showers maintained. Observed broken shower handle corrected on site.

34 - inspection report placed in public view

Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

1 ptsCorrected: YesRepeat: No

13-187(c); Code says inspection report placed and in public view. Observed inspection report corrected on site (COS) and placed in public view.

Aug 4, 2023

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): Code says an adequately sized flow meter must be placed on the return line -Observed flow meter to be to small -Must be able to read 137.5gpm

Aug 1, 2023

Permit/Opening

Score: 802 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): Code says pH must be between 7.2-7.8 -First Reading: 6.6 -Second Reading: 8.6

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): Code says an adequately sized flow meter must be placed on the return line -Observed flow meter to be to small -Must be able to read 137.5gpm