Scottdale, DeKalb County

PACES PARK APARTMENTS

100 PACES PARK DR DECATUR, GA 30033

Pool
Latest score
100
May 21, 2026
City
Scottdale
County
DeKalb
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 21, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 19, 2026

Permit/Opening

Score: 852 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The pool shall be maintained in an alkaline condition at all times with a pH level between 7.2 – 7.8. Observed pH at 7.1.

9 - filter: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

13-190(a): All circulation system components, including filter(s), pump(s), hair lint strainer(s) and other similar components, shall function properly and be maintained in a clean condition. Observed hose continuously becoming disconnected and leaking water.

May 22, 2025

Permit/Opening

Score: 912 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): Observed flow rate at 60gpm on a pool that shares a pump system with a fountain. This calculates a turnover rate of 11.11 hours. CA: The equipment shall be operated continuously on a twenty-four (24) hour basis to obtain the minimum required number of four (4) turnovers per day, or one turnover every six (6) hours (pools);ever four(4) hours for pools with features; every 30 mins. for spas.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196(a)(4): Observed skimmers missing weirs. CA: Each skimmer shall have a properly designed and operating weir or other departmentally approved means of providing effective skimming.

Jun 30, 2023

Re-inspection

Score: 991 violation

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

Missing baby changing station in women and men's restroom.

Jun 30, 2023

Permit/Opening

Score: 815 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: YesRepeat: No

511-3-5-.18(11)(h) - (h) Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. At the time of inspection two of the pool entrance gate did not latch properly.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: YesRepeat: No

At the time of inspection, rope was not attached to the buoy.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: YesRepeat: Yes

Unsecured handrails considered an imminent health hazard-safety hazard.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(n) - (n) sanitary facility fixtures and dressing area fixtures and furniture shall be cleaned and sanitized with an epa-approved product and as needed to provide a clean and sanitary environment.

1 ptsCorrected: NoRepeat: No

Missing baby changing station in women and men's restroom.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

#37 Violation: Contact information not located near pool Emergency phone.