Douglasville, Douglas County

SLATER MILL COMMUNITY ASSOC (PHASE II POOL))

8715 DANLEY DR DOUGLASVILLE, GA 30135

Pool
Latest score
100
Apr 24, 2026
City
Douglasville
County
Douglas
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 24, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 20, 2025

Permit/Opening

Score: 982 violations

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

Observed no hand drying provisions in bathrooms. CA: Provide hand drying provisions

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed back gate with space underneath. CA: Must be fixed to close gap.

Aug 30, 2024

Re-inspection

Score: 932 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed float in flow meter appears stuck. CA: Ensure not stuck-correct gpm must be displayed

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Observed pool risk signs and supervise children signs not posted. CA: Signs must be posted

Aug 14, 2024

Routine

Score: 815 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone dialing but no way to hear operator. CA: The emergency phone shall be capable of connecting to 911

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine at 0ppm. CA: Chlorine must be maintained between 2-10ppm

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH low at 7.0 CA: pH must be maintained between 7.2-7.8

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed handrail loose. CA: Handrails shall be installed in such a way that they cannot be removed without the use of tools.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Observed pool risk, hours/bather load signs removed and stored on tables. CA: Signs must be posted clearly visible

May 15, 2024

Permit/Opening

Score: 925 violations

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Weirs missing in Skimmers. CA: install Weirs.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

Observed ladders missing boot caps. CA: install boot caps.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(n) - (n) sanitary facility fixtures and dressing area fixtures and furniture shall be cleaned and sanitized with an epa-approved product and as needed to provide a clean and sanitary environment.

1 ptsCorrected: NoRepeat: No

Observed no towels in restroom. CA: Clean and stock restrooms.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Light burnt out. CA: Replace light

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Brush walls and sides of pools due to algae growth.

Aug 22, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 16, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.