May 19, 2026
Permit/Opening
14 - vacuum line protected
Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.
The vacuum line is not covered with the correct fitting. The vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current IAMPO SPS 4- Special Use Suction Fitting for Swimming Pools, Spas and Hot Tubs.
15 - depth and no diving markers, step marking; installed and contrasting
Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.
The letters on the depth marker do not meet minimum height requirement of 4". Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Correct prior to permitting season 2028
21 - cyanuric acid level not exceeding maximum
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
The cyanuric acid level exceeds the maximum allowance of 90 ppm. Reduce CYA to get maximum effectiveness of the chlorine. Stabilizer (if used) Cyanuric acid, ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or brominated pools and spas.
22 - signs: peak occupancy/pool/spa/signs legible and in clearview
Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
The words "No Diving" does not meet the minimum height requirements for the depth markers. The No Diving marking and universal symbol for No Diving is not permanent in nature on the deck; slip resistant stickers are used- are easily peeled off. The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.
22 - signs: peak occupancy/pool/spa/signs legible and in clearview
Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis
The "No Lifeguard on Duty" sign does not meet the code requirements. Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.
37 - other violations of the chapter
.11(3)(e) There is no equalizer check valve and float valve assembly present in each skimmer. Each skimmer shall be equipped with a trimmer valve capable of distributing the total flow between individual skimmers.