Nov 19, 2025
Routine
6-2 - proper date marking and disposition
Regulation: 511-6-1.04(6)(g) - ready-to-eat time/temperature control for safety food, date marking (pf)
Observed that the facility is date marking items for 8 days instead of 7. COS. Date labels fixed. CA: Prepared TCS food and opened manufactured TCS food shall be date marked for no more than 7 days with the day of preparation being day 1.
12C - wiping cloths: properly used and stored
Regulation: 511-6-1.04(4)(m) - wiping cloths, use limitation (c)
Observed wet wiping cloths stored in only soapy water. COS. Sanitizer added. CA: Wet wiping cloths shall be stored in sanitizer solution at the correct concentration between uses.
16B - plumbing installed; proper backflow devices
Regulation: 511-6-1.06(2)(r) - system maintained in good repair (p, c)
Observed that one of the hand sinks in the kitchen was turned off and labeled as do not use due to a leak; observed that the 3-compartment sink at the bar and in the kitchen had leaks/drips, the bar sink has a continuous drip and the kitchen sink has a continuous drip and is leaking from around the base of the faucet/handles. CA: Plumbing system and fixtures shall be maintained in good repair.
16C - sewage and waste water properly disposed
Regulation: 511-6-1.06(4)(h),(i) - approved sewage disposal; system; other liquid wastes and rainwater (p) (c)
Observed that the facility is having a back up of waste water at what appears to be the lowest point in the plumbing system, the drains at the dumpsters, and the surfacing wastewater is draining directly into the storm drains. CA: Wastewater shall be appropriately disposed of.
17B - garbage/refuse properly disposed; facilities maintained
Regulation: 511-6-1.06(5)(o),(p) - using drain plugs; maintaining refuse areas (c)
Observed that not all of the dumpsters had drain plugs in the dumpster drains. CA: When present, dumpster drains shall have drain plugs in them.
17C - physical facilities installed, maintained, and clean
Regulation: 511-6-1.07(5)(a),(b) - good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)
Observed accumulation of debris under equipment at the bar and in the walk-in freezer; observed broken tile of coving by walk-in. CA: Floors shall be thoroughly cleaned and cleaning frequency shall be enough to prevent build up; facility shall be maintained in a state of good repair.