Jun 10, 2026

Permit/Opening

Score: 755 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

The pH does not meet minimum requirement of 7.2ppm. Must be corrected prior to re-inspection. pH should be maintained between 7.2 and 7.8. Must be corrected prior to permitting.

14 - vacuum line protected

Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.

5 ptsCorrected: NoRepeat: No

The vacuum line is not covered with the correct fitting. The vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current IAMPO SPS 4- Special Use Suction Fitting for Swimming Pools, Spas and Hot Tubs.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(g) - (g) a minimum four foot deck width shall be provided on the sides and rear of any diving equipment or waterslide stairs. a deck clearance of forty-eight inches shall be provided around all deck equipment.

2 ptsCorrected: NoRepeat: No

Pool chairs are present right at the pool's edge. Chairs must be pushed back to allow a 4 ft continuous walking space around pool. The deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

The "No Lifeguard on Duty" sign does not meet the code requirements; letter height is not at least 4 inches. Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.17(2): The is insufficient calcium hardness in the pool. hardness is required to be at 150 ppm minimum and 1000 ppm maximum. Speak with CPO about adjusting calcium in the pool.

Mar 24, 2026

Permit/Opening

Score: 697 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: Yes

The emergency box connects to a third party emergency provider and not directly to 911. An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby. This item must be corrected prior to permitting.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

The turnover is not sufficient for the pool. The minimum turnover rate for the pool is 92 gpm. Ensure the minimum turnover rate is always maintained.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

There is no available documentation to verify a daily safety check is conducted. A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet. See CPO Guidance Docs.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

There is no available documentation to verify the daily chemical testing is done as required. The chlorine and pH must be tested twice daily for pools. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. The water quality testing frequency shall be as indicated in the CPO guidance document.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

There is no available documentation to verify the CPO is checking the required information as indicated in the code. Written documentation of the operator’s visits must be available at the pool facility. At a minimum, the written record must indicate the condition of the following items: circulation, filtration, disinfection systems, safety equipment onsite, pool stairs and deck condition, water chemistry results, and corrective actions taken, if needed. This information must be documented at least twice weekly.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: Yes

The incorrect No lifeguard on duty sign is posted. The first portion of the required sign is posted in the correct sizing, but the "Risk of Drowning- Supervise Children Closely" is not present. Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

There is no sign indicating the bather load, nor the hours of operation. The peak occupancy for the pool is 55. A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy

Jul 22, 2025

Re-inspection

Score: 832 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

The emergency box connects to a third party emergency provider and not directly to 911. An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: Yes

The incorrect lifeguard on duty sign is posted. Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

Jun 30, 2025

Routine

Score: 6912 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

The emergency box connects to a third party emergency provider and not directly to 911. An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

The chlorine level does not meet minimum requirements for a stabilized pool. The minimum is 2.0 ppm for chlorine. During operation, disinfectant levels are less than the minimum level specified in DPH Rule 511-3-5-.17. If the level of the disinfectant used is not specified in DPH Rule 511-3-5-.17, the disinfectant must be approved and kept at levels determined necessary by the health authority.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

During operation, the pH is less than the minimum levels allowed in DPH Rule 511-3-5-.l7. The minimum allowed is 7.2.

8 - chemical feeder operational and approved

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

The chemical feeder is not functioning properly. There are chlorine tabs present in the pool skimmers. Chlorine must be continuously fed to the pool through the feeder and can not be added directly to the pool for continual use.

9 - filter: approved, maintained and operating

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

There is no pressure on the filter pressure gauge. The air release valve is opened and no water comes into the viewing port. This indicates an issue with the filter. Ensure the filter is properly functioning at all times.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.

15 ptsCorrected: NoRepeat: No

The body hook that is attached to the strong pole is broken. The body hook must be intact to properly function.

14 - vacuum line protected

Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.

5 ptsCorrected: NoRepeat: No

The vacuum port present on the pool at the long step is not properly covered.The vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current IAMPO SPS 4- Special Use Suction Fitting for Swimming Pools, Spas and Hot Tubs.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

The flow meter is not properly functioning and the flow can not be determined. The minimum turnover rate for the pool is 92 gpm. Ensure the minimum turnover rate is always maintained.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

A weir is not present in each skimmer. Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

The float valve assemblies and the equalizer check valves are not present in each skimmer. When equalizer lines are present, all equipment must also be present in the skimmer to ensure the functionality of the equalizer lines.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

The incorrect lifeguard on duty sign is posted. Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Not all required Pool Risks are properly posted. Ensure all required Pool Risks indicated in the Code are present on the sign. The sign will state under the heading “Pool Risks” the following items in clearly legible letters at least one inch high:

Mar 14, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Mar 11, 2025

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Must have operational hard wired phone. Phone call receiver can hear caller but operator cannot heard at pool. Repair phone. Reinspection required to verify operational phone.

Sep 24, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 7, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.