Peachtree City, Fayette County

Braelinn Golf Club (Slide Pool)

500 CLUBVIEW DR PEACHTREE CITY, GA 30269

Pool
Latest score
96
May 11, 2026
City
Peachtree City
County
Fayette
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 11, 2026

Permit/Opening

Score: 961 violation

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

A weir is not present in each skimmer. Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

Aug 26, 2025

Re-inspection

Score: 894 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed that the flow meter was not working/stuck. CA: Flow meter shall be functional and able to read the flow through the system.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: .06(3)(e) - markings

4 ptsCorrected: NoRepeat: Yes

The entirety of the outer two inches of the steps are not marked with contrasting color. CA: The outer two inches of the pool steps shall be marked in a contrasting color. This must be corrected prior to next season.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: Yes

Observed that the peak occupancy sign was not posted. CA: The peak occupancy sign shall be posted.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: Yes

Observed not all pool risks were posted and verbiage was not an inch tall. CA: All pool risks shall be posted and be of the correct size.

Jun 23, 2025

Re-inspection

Score: 5719 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: Yes

The gate where attendant sits is left unlocked and the pool is accessible to the public. There must be a self latching mechanism that ensures the gate is closed all the way. The staff gate is also left unlocked and there is no self latching mechanism to prevent the entry of the public into the pool. No attendants are present and no lifeguards are on duty. The presence of attendants and life guards to not negate the need for the self closing, self latching gates. However, there is no excuse for these gates remaining unlatched after the routine inspection that occurred on 6/11/25. The pool must remain closed until these gates can be properly functioning. The main gate is locked (this gate now opens outward). The locking mechanism must be at least 54 inches high for mechanisms on exterior of gate. If the release mechanism is located on the pool side of the gate, it must be at least 3 inches below the grade of the gate. For the time being, it is safer to use the main gate that opens inward, but has the proper latching mechanism and the other two gates must be chained/locked.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: Yes

There is no emergency phone available to contact 911. The food service area is not open at this time. The land line phone that is present in the food area, must be extended to the exterior of the building and remain accessible on the exterior of the building. It must also be properly marked as an emergency phone. A designated 911 phone should be installed prior to next season unless the current land line phone remains on the exterior of the food service area (within the pool enclosure). The manager has ordered the software and line for an emergency phone.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: Yes

There is no available chlorine present in the pool. The minimum required is 2 ppm.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: Yes

The pH is 7.0. The minimum required pH is 7.2

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.

15 ptsCorrected: NoRepeat: Yes

the body hook had the hook removed from the pole. CA: There shall be a strong pole with a body hook on it.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

A safety inspection is not performed daily. A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

There are no documents available for the required testing by the responsible person. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type

5 ptsCorrected: NoRepeat: No

The flow of the pool does not meet minimum turnover requirements to turn pool over every 4 hours. The minimum turnover must be 320 gpm.

35 - operator facility inspections performed; written documentation

4 ptsCorrected: NoRepeat: No

The documents for the CPO visits are not available. See Guidance for details.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

the entirety of the outer two inches of the steps are not marked with contrasting color. CA: The outer two inches of the pool steps shall be marked in a contrasting color. This must be corrected prior to next season.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

A weir is not present in each skimmer. Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

The float valve assemblies and equalizer check valves are not present under each basket in the skimmers. Provide the necessary equipment in each skimmer for proper functioning of the equalizer lines.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: Yes

The universal no diving symbol is not present on the pool deck. The universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

Lifeguards are not on duty at the beginning of the inspection. However, there are swimmers. Since the pool is open to swimmers when lifeguards are not on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

Lifeguards are not on duty at the beginning of the inspection. However, there are swimmers. Since the pool is open to swimmers when lifeguards are not on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

The facility does not have the complete list of required pool Risks posted. Facility shall have the pool risks posted in at least inch tall lettering.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: Yes

The ladder on the far end of the slide pool pulls up out of the concrete a bit. Handrails shall be fixed in place and, if they are removeable, shall only be removeable by the use of tools.

24 - piping identified and marked

1 ptsCorrected: NoRepeat: Yes

Observed arrows missing from piping. CA: Piping shall have directional arrows.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.17(2): The alkalinity does not meet minimum requirement of at least 60ppm. Correct alkalinity before correcting pH.

Jun 11, 2025

Routine

Score: 7110 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed that a gate was left open without self-closing mechanisms and staff states that its for employees only but is left open to the public, a gate opens inwards, and one gate was left open with an attendant there. CA: Gates shall be self-closing and self-latching without exception.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed that there was a landline phone in the food service area to contact 911, however, the phone is not labeled or marked as such and inaccessible to the public. CA: A emergency phone shall be properly installed, marked, and made accessible to the public prior to the next pool season.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.

15 ptsCorrected: NoRepeat: No

Observed that the body hook had the hook removed from the pole. CA: There shall be a strong pole with a body hook on it.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: .06(3)(e) - markings

4 ptsCorrected: NoRepeat: No

Observed that the entirety of the outer two inches of the steps are not marked with contrasting color. CA: The outer two inches of the pool steps shall be marked in a contrasting color.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

Observed that the operator visit records are unavailable. CA: Operators records shall be available.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed that ladders would slide up and down several inches, one of them almost 12 inches. CA: Handrails shall be fixed in place and, if they are removeable, shall only be removeable by the use of tools.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Observed that the facility does not have the proper pool risks/rules posted. CA: Facility shall have the pool risks posted in at least inch tall lettering.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Observed that the the words for no diving and the international no diving symbol were not at all depths markers less than 5 ft. CA: The no diving and international no diving symbol shall be present at depth markers in areas where it is less than 5 feet.

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Observed arrows missing from piping. CA: Piping shall have directional arrows.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed alkalinity was 30 ppm. CA: Alkalinity shall be 60 ppm to 180 ppm.

Apr 28, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 14, 2024

Routine

Score: 851 violation

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: YesRepeat: No

Chlorine level at 0.5ppm upon arrival. Pool closed. Chemicals added to raise chlorine while pool was closed. Rechecked. Okay to reopen pool since adjusted to 3.5ppm.

Apr 18, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 13, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.