Peachtree City, Fayette County

Cresswind Clubhouse (Indoor Spa)

101 CRESSWIND BLVD PEACHTREE CITY, GA 30269

Pool
Latest score
98
Apr 24, 2026
City
Peachtree City
County
Fayette
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 24, 2026

Permit/Opening

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

The words "No Diving" does not meet the minimum height requirements for the depth markers. The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. These must be in compliance prior to permitting 2028.

Apr 16, 2026

Permit/Opening

Score: 779 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

The emergency phone does not properly dial 911 emergency operator. An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

There is no available documentation to verify a daily safety check is conducted. A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet. See CPO Guidance Docs.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

There is no available documentation to verify the daily chemical testing is done as required. The chlorine and pH must be tested twice daily for pools. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. The water quality testing frequency shall be as indicated in the CPO guidance document. See email. For spas and hot water venues, free available chlorine, total bromine, pH and water temperature shall be tested prior to opening and recorded every four hours.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

The words "No Diving" does not meet the minimum height requirements for the depth markers. The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. These must be in compliance prior to permitting 2028.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(b) - (b) warning signs for spas shall be in clear view of the spa and prominently displayed. signs shall state the spa's address, the location of the nearest telephone with references that emergency telephone numbers are posted at the location. these emer

2 ptsCorrected: NoRepeat: No

The required spa risks sign is not posted. See email for additional information on sign requirements. Warning signs for spas shall be in clear view of the spa and prominently displayed. Signs shall state the spa's address, the location of the nearest telephone with references that emergency telephone numbers are posted at the location. These emergency telephone numbers should include the name and phone number of the nearest available police, fire or ambulance service, and "911" if available. Signs shall include, but not be limited to the following messages: (See email)

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.11(3)(e) There is no equalizer check valve and float valve assembly present in each skimmer. Each skimmer shall be equipped with a trimmer valve capable of distributing the total flow between individual skimmers.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

The total alkalinity exceeds the maximum allowance of 180ppm. Reduce alkalinity to a level between 60-180ppm.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.18(5) There is no clock available for spa bathers. All public facilities shall have a functioning clock which is visible to spa users.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.13(2)(c) There is no thermometer available to monitor the spa water temperature. The spa operator shall be provided with an accurate thermometer (±1 degree F tolerance) and shall periodically check to ensure that the maximum temperature does not exceed 104 degree F.

May 30, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Dec 31, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 23, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 6, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jan 8, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 6, 2023

Routine

Score: 991 violation

34 - inspection report placed in public view

Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

1 ptsCorrected: NoRepeat: No

Post inspection report in view of pool.