Tyrone, Fayette County

River Crest

230 STONEWYCK DR TYRONE, GA 30290

Pool
Latest score
98
Apr 14, 2026
City
Tyrone
County
Fayette
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 14, 2026

Permit/Opening

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. These must be in compliance prior to permitting 2028.

Aug 18, 2025

Routine

Score: 7012 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.23(5)(g) - (g) failure to provide and maintain a barrier to inhibit unauthorized access to the outdoor facility when required.

15 ptsCorrected: NoRepeat: No

Observed that the door from the event space into the pool enclosure is not properly inhibiting unauthorized access. The door is not marked or indicated that it is to remain locked at all times and all access controls are less than 54 inches from the ground and the door does not close. Recommended actions: If the door is to be used for access into the pool enclosure, the door shall self-close and self-latch and either the lock or the no touch access needs to be 54 inches above ground level; a number pad or other locking mechanism could be used as well. Alternatively, the door can always remain locked and indicated as such and all pool entry can be through the standard pool gates. CA: Facility shall inhibit unauthorized access by providing and maintaining a barrier.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed that the emergency phone does not call 911, it calls an independent third party company instead. CA: An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Observed that the chlorine in the pool was 0.5 PPM. CA: For a stabilized pool, chlorine disinfectant shall be betweeen 2 PPM and 10 PPM.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed that the pH was 8.0. CA: pH shall be between 7.2 and 7.8

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Observed that there is no available information to verify a daily safety check is being performed. CA: A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed there are no available records onsite to verify twice daily chemical testing is performed. CA: The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. The water quality testing frequency shall be completed based on the requirements of the code.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

Observed that the skimmer equalize lines were not protected by the float valve assembly. CA: Skimmer lines shall be properly protected.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

Observed that one of the pressure gauges was not functioning. CA: A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

Did not observe the CPO records. CA: Written documentation of the operator’s visits shall be available at the pool facility.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

Observed that the life guard signage is incorrect/incorrect height. CA: Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Observed that the correct pool risks are not correct. CA: The pool risks with all required verbiage and required height of letters shall be posted.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed that the peak occupancy sign did not have the number on it and hours were not posted. CA: Pool hours shall be posted and peak theoretical occupancy shall be posted.

May 5, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Apr 14, 2025

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Must have operational phone line. Reinspection required.

Jul 19, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Apr 11, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 7, 2023

Routine

Score: 951 violation

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Provide records of daily water testing

May 23, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.