Atlanta, Fulton County

77 12th Street

77 12TH ST NE ATLANTA, GA 30309

Pool
Latest score
100
May 6, 2026
City
Atlanta
County
Fulton
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 6, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 19, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Apr 29, 2025

Permit/Opening

Score: 783 violations

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.

15 ptsCorrected: NoRepeat: No

Observed the shepherds hook not securely attached to the pole. CA- shepherds hook shall be securely attached to the pole. 511-3-5-.18(10)(a) - (a) A light, strong pole not less than twelve feet long including body hook. (a) A light, strong pole not less than twelve feet long including body hook.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed the flow meter stuck at the bottom and not able to achieve the appropriate range. Ca- flow meter shall be replaced. 511-3-5-.07(4)(b) - (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

Observed no no lifeguard on duty sign risk of drowning supervise children closely. CA- sign should be placed. 511-3-5-.18(12)(b) - (b) Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVIS (b) Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

May 15, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 16, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jun 9, 2023

Permit/Opening

Score: 802 violations

4 - water clarity: main drains clearly visible

Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e

15 ptsCorrected: NoRepeat: No

Observed cloudy pool with main drain not visible. Advised PIC main drain shall be clearly visible.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: Yes

Observed flow meter measuring 0 gpm. Advised PIC turnover rate shall be 6 hours.

May 31, 2023

Permit/Opening

Score: 802 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed 0 ppm for chlorine in pool. Advised PIC chlorine levels shall be between 2 - 10 ppm

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type

5 ptsCorrected: NoRepeat: No

Observed inadequate turn over rate, advised to repair.