Atlanta, Fulton County

St. Regis Hotel & Residences Spa

88 WEST PACES FERRY ATLANTA, GA 30305

Pool
Latest score
100
Apr 8, 2026
City
Atlanta
County
Fulton
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 8, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Mar 4, 2026

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

No record of annual gas fired equipment inspection having been performed on heater. Corrective action - PIC advised to schedule inspection and provide a copy of the confirmation document to Health Authority as soon as possible.

Jun 12, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 9, 2025

Permit/Opening

Score: 783 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed the pH to low on the hot tub. CA- pH shall be between 7.2-7.8. 511-3-5-.17(2) - (2) Chemical Values: pH (2) Chemical Values: pH 7.2 7.4-7.6 7.8 Alkalinity (buffering), 60 ppm 80-100 halogens compounds with high pH 180 ppm as CaC03 100-120 halogen compounds with low pH Calcium hardness, ppm, CaCo3 150 200-400 to balance water 1000

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed the flow meter not working at the time of the inspection. CA- flow meter shall be replaced and be in the appropriate range. 511-3-5-.07(4)(b) - (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

Observed missing wording on the no lifeguard on duty sign. The sign was missing risk of drowning supervise children closely. CA- correct sign must be posted. 511-3-5-.18(12)(b) - (b) Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVIS (b) Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

May 8, 2024

Permit/Opening

Score: 851 violation

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed several chemical values that were not in there recommended ranges. See chemical log for the readings. pH 7.2 7.4-7.6 7.8 Alkalinity (buffering), 60 ppm 80-100 halogens compounds with high pH 180 ppm as CaC03 100-120 halogen compounds with low pH Calcium hardness, ppm, CaCo3 150 200-400 to balance water 1000

PIC will rebalance the spa

Nov 20, 2023

Routine

Score: 961 violation

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

Observed no CPO cert upon request. (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority. PIC will ensure that all CPOs have their certs on file at the facility.