Columbus, Muscogee County

SpringHill Suites

5415 WHITTLESEY BLVD COLUMBUS, GA 31907

Pool
Latest score
100
Oct 2, 2024
City
Columbus
County
Muscogee
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Oct 2, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Aug 29, 2024

Re-inspection

Score: 961 violation

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed skimmer lacking a weir gate. Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. Corrective action: Weir gate shall be replaced within 30 days. Person in charge stated they will be installed today.

Aug 20, 2024

Routine

Score: 804 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed gate latch sliding out of place causing the gate not to self-latch. Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self latching device is located less than fifty-four inches from the bottom of the gate, 1. The release mechanism shall be located on the pool side of the gate at least three inches below the top of the gate and 2. Any openings in the gate or barrier located within eighteen inches of the release mechanism shall be less than one-half inch. 3. Mechanisms controlled by an access card reader, key entry device or keypad shall be located on the outside of the access gate.

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed free chlorine level at 0.2 ppm. Free chlorine,ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5. (b) All public pools except as listed below: Minimum 1.0 Ideal 1.0-3.0 Maximum 10.0

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Observed total alkalinity level at 40 ppm. Pool shall have a total alkalinity range between 60-180 ppm.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter with a flow indicator not moving. A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

May 31, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.