Watkinsville, Oconee County

WISTERIA RIDGE

1062 WISTERIA RDG WATKINSVILLE, GA 30677

Pool
Latest score
100
Apr 10, 2026
City
Watkinsville
County
Oconee
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 10, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 17, 2025

Routine

Score: 5610 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

CHLORINE 12.5, WAY TOO HIGH

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

pH LEVELS BELOW 7.2

9 - filter: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

FILTER WAS NOT ON AT TIME OF INSPECTION

10 - pump: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

PUMP WAS NOT ON AT TIME OF INSPECTION

18 - combined chlorine level 0.4 ppm or less

5 ptsCorrected: NoRepeat: No

COMBINED CHLORINE 1 PPM

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

PUMP NOT ON

23 - automated controller operational; pumps interlocked

5 ptsCorrected: NoRepeat: No

AUTOMATED CONTROLLER AND PUMPS NOT OPERABLE/ON

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

FLOW METER AT 0, PUMP AND FILTER NOT ON

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

NO DAILY RECORD KEEPING

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

CYA ABOVE 100PPM

May 2, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 14, 2024

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

FLOW METER NOT WORKING. PLEASE REPLACE.

Apr 23, 2024

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

911 dispatch does not show pool as the location for the phone.

Sep 12, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Sep 5, 2023

Routine

Score: 813 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

FAC LEVELS BELOW 2.0 PPM

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

pH LEVELS BELOW 7.2

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

CYA ABOVE 100PPM