Augusta, Richmond County

DOUBLE TREE HOTEL OF AUGUSTA INDOOR POOL 1

2651 PERIMETER PKWY AUGUSTA, GA 30909

Pool
Latest score
100
Apr 6, 2026
City
Augusta
County
Richmond
Inspections
19

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 6, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Nov 17, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Nov 14, 2025

Routine

Score: 851 violation

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

pH < 7.0

May 22, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 19, 2025

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Adjust total alkalinity, calcium hardness (TA min. 60ppm, Hardness 150-1000 ppm).

Apr 24, 2025

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

Phone works except when outdoor handset off hook. Phones must be able to dial local 911 system at all times.

Apr 17, 2025

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

Phone not operable; repair to be able to access local 911 system. Advise placing 911 phones on separate lines (outside line was off hook; inside worked when outside put on hook).

Apr 15, 2025

Permit/Opening

Score: 804 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Door at back of pool room does not latch (magnetic).

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Pool shocked this am due to low initial reading.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Need new rope on throw ring.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Unstick flowmeter float, replace meter as needed to give accurate reading.

Mar 17, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Mar 13, 2025

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Need new reagents (several expired) (DPD #2 exp. 11/20, pH on 11/24).

Jan 27, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Dec 16, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Sep 3, 2024

Routine

Score: 802 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: YesRepeat: No

pH < 6.8. Added ~ 2.5 lbs soda ash to correct pH.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Keep 2x/day records of pH, chlorine.

Jun 11, 2024

Routine

Score: 852 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Adjust pH to 7.2-7.8 range. Adjust TA to above 60 ppm.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Untangle throw ring rope. Rope must be 1 1/2 times widest width of pool.

Feb 16, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jan 19, 2024

Permit/Opening

Score: 912 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Repair flowmeter.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Need "No Diving" at shallow end (4" letter, 1" stroke).

Dec 8, 2023

Routine

Score: 802 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: YesRepeat: No

pH=7.0; added 2lbs soda ash to increase pH. Keep pH 7.2-7.6

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Unstick flowmeter float.

Aug 22, 2023

Routine

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Decrease cya level to <90ppm

May 31, 2023

Routine

Score: 852 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: YesRepeat: No

Added soda ash to increase pH (~1.5 lbs).

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: YesRepeat: No

Untangle throw ring rope.